Preparation and biodistribution assessment of low specific activity 177Lu-DOTATOC for optimization studies
محل انتشار: مجله پزشکی هسته ای ایران، دوره: 24، شماره: 2
سال انتشار: 1395
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 414
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IRJNM-24-2_002
تاریخ نمایه سازی: 21 بهمن 1398
چکیده مقاله:
Introduction: Somatostatin receptors expressed on a wide range of human tumors, are potential targets for the peptide receptor radionuclide therapy (PRRT). In this study, 177Lu-[DOTA-DPhe1, Tyr3]octreotide (177Lu-DOTATOC) as an agent for PRRT was prepared and its biodistribution was studied in rats.
Methods:The best condition for the preparation of the 177Lu-DOTATOC radiolabeled complex was determined by various experiments. Radiochemical purity of the radiolabeled complex was checked using ITLC method. The stability of the complex in room temperature and in human serum was studied up to 48 h. The biodistribution of 177Lu-DOTATOC solution was investigated in male rats at each selected interval time (2, 4, 24, 48, 72 and 168 h) after injection and compared with the biodistribution of 177LuCl3 solution in the same-type rats.
Results:177Lu-DOTATOC was prepared successfully with radiochemical purity of higher than 99% in 30 min at the optimized conditions. The stability of the radiolabeled complex at room temperature and in human serum at 37 °C showed no decrease in the radiochemical purity even after for 48 h. The biological behavior of the complex showed a major difference uptake with 177LuCl3 solution especially in the liver and spleen and also in somatostatin receptor-positive tissues such as pancreas and adrenal.
Conclusion: The results showed that 177Lu-DOTATOC has the comparable pharmacokinetic with the other DOTATOC complexes, while has completely different pattern compared with 177Lu cation.
کلیدواژه ها:
نویسندگان
Hassan Yousefnia
Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran
Masoumeh-Sadat Mousavi-Daramoroudi
Radiation Application Group, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran
Samaneh Zolghadri
Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran
Fereydoun Abbasi-Davani
Radiation Application Group, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :