Hierarchical flowerlike cobalt oxide derived layered double hydroxide on nanoporous anodized aluminum oxide / aluminum film as thin film microextraction sorbent

سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 375

متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

CMTS02_059

تاریخ نمایه سازی: 29 تیر 1398

چکیده مقاله:

Among the available metal oxide as the sorbent for microextraction purposes, cobalt oxide/hydroxide is desirable candidates due to its natural abundance, low cost, large surface-to-volume ratio, good adsorption ability, high stability and environmental compatibility [1]. These unique features of Co3O4 make it suitable for the extraction or removal of organic compounds in the aqueous samples. In this study, hierarchical flowerlike cobalt oxide coated anodized aluminium foil was prepared by in-situ conversion of fabricated Co-Al layered double hydroxide as template. The Al foil substrate was anodized using fast electrochemical technique such as amperometric method. the, Co-Al-LDH precursor has been fabricated on nonporous anodized aluminum film via the in-situ crystallization technique. The prepared flowerlike cobalt oxide was used as a novel sorbent in thin film microextraction (TFME) method followed by HPLC-UV after its extracted by TFME method. After extraction, the extracting film was eluted using organic solvent to desorb the target analyte. In order to evaluate the extraction ability of the prepared film, diclofenac was selected as model analyte. Therefore diclofenac was determined by high performance liquid chromatography-ultraviolet detection (HPLC-UV). Plackett–Burman design was used for screening the experimental factors of interest. The screened factors were then optimized using Box-Behnken design (BBD). To investigate the capability of the prepared film for determination of diclofenac as analyte in real sample analysis, urine and plasma samples were selected as real samples.

کلیدواژه ها:

HPLC ، Thin film microextraction ، Nonoporous anodic aluminum oxide ، Diclofenac ، Co3O4

نویسندگان

Faezeh Alipour

Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran

Jahan Bakhsh Raoof

Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran

Milad Ghani

Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran