Design and Development of an Indigenous in-house Tissue-Equivalent Female Pelvic Phantom for Radiological Dosimetric Applications
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 15، شماره: 3
سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 335
فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-3_010
تاریخ نمایه سازی: 18 تیر 1398
چکیده مقاله:
Introduction: The present study is aimed to design and develop a tissue-equivalent pelvic phantom, mimicking the Indian female pelvic dimensions by means of locally available and cost-effective tissue substitutes having equivalent radiological properties. Materials and Methods: For the purpose of the study, the real female pelvic bones were embedded for preparation. Paraffin wax, Aloe-vera powder, purified borax, and sodium benzoate, were used to obtain the proper density and effective atomic number. A hollow three-dimensional outer surface and the internal organs moulds were fabricated using gypsona bandage. The internal organs moulds were filled with semi-solid paraffin wax mixture, stabilized, and then embedded with pelvic bones and internal organs at the right anatomical positions. The surface mould, along with the bones and internal organs, were stabilized in their position in the final form, and verified with computed tomography (CT). Results: The physical dimensions of the given female pelvic phantom were comparable with the mean dimensions of the Indian female pelvis. Furthermore this tissue-equivalent phantom was radiologically equivalent to the Indian human female pelvis in all respects. The CT numbers of the uterus, bladder, rectum, muscles, fats, bone, and cavities were 39.9, 30.5, 24.7, 34.6, -86.8, 578.6, and -220.9 HU, respectively. Furthermore, the relative electron densities of the muscle, fat and bones were 1.035, 0.913, and 0.779 in the phantom. Conclusion: The dimensions and physico-radiological properties of the tissue substitutes provided a good inhomogeneous female pelvic phantom differing in dimensions with imported pelvic phantoms. Therefore, this phantom can be used for radiological dosimetric applications.
کلیدواژه ها:
نویسندگان
DEEPAK SHROTRIYA
DEPARTMENT OF PHYSICS, D.A-V. (P.G.) COLLEGE KANPUR (U.P.)- ۲۰۸۰۰۱
Ram Yadav
Department of Physics, D A-V PG College Kanpur
R SRIVASTAVA
Department of Radiotherapy J.K. Cancer Institute Gutaiya, Rawat Pur, Rawatpur Main Road, Kanpur, Uttar Pradesh ۲۰۸۰۱۹
Teerth Verma
Department of Radiological Physics, king George Medical University, UP; Lucknow-۲۲۶۰۰۳ INDIA
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :