Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to verify the doses calculated by different algorithms. Objective: This study aims to compare the planed dose using different algorithms with measured dose using an indigenous heterogeneous pelvic phantom.Material and Methods: In this experimental study, various three dimensional conformal radiotherapy (۳D-CRT) plans were made using different doses calculated by algorithms. The plans were delivered by medical linear accelerator and doses were measured by ion chamber placed in the indigenous pelvic phantom. Planned and measured doses were compared with together and analyzed. Results: The relative electron densities of different parts in the pelvic phantom were found to be in good agreement with that of actual pelvic parts, including bladder, rectum, fats and bones. The highest percentage deviations between planned and measured dose were calculated in the single field for Superposition algorithm (۳.۰۹%) and single field with ۴۵˚wedge for Superposition (۳.۰۴%). The least percentage deviation was calculated in the opposite field for Convolution which was - ۰.۰۸%. The results were within the range of ±۵% as recommended by International Commission on Radiation Units and Measurement. Conclusion: The cost-effective indigenous heterogeneous pelvic phantom has the density pattern similar to the actual pelvic region; thus, it can be used for routine patient-specific quality assurance.
کلیدواژه ها:
نویسندگان
S Singh
PhD, Department of Physics, Ranchi University, Ranchi- ۸۳۴۰۰۸, Jharkhand, India
P Raina
DipRP, Research Scholars, University Department of Physics, Ranchi University, Ranchi- ۸۳۴۰۰۸, Jharkhand State, India
O P Gurjar
PhD, Department of Radiotherapy, AIIMS, Bhopal- ۴۶۲۰۲۰, Madhya Pradesh, India
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :