Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 357

فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-3_006

تاریخ نمایه سازی: 18 تیر 1398

چکیده مقاله:

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector element sizes, scintillator material, impurities in the scintillator material, and the material of detector separators on X-ray crosstalk. Materials and Methods: This study was performed using Monte Carlo simulation. In the first step, X-ray tube and its energy spectrum at the energies of 80, 100, 120, and 140 keV were simulated and validated by using SpekCalc and t-test. Then, other important parts of CT scanner, namely filters, detectors, and grids were simulated. X-ray crosstalk between CT detectors was calculated in air and in the presence of water phantom (as a simulator of human body) to compare the effect of scattered photons. Finally, the influence of some important parameters on X-ray crosstalk was evaluated. Results: In CT scanner with small elements, when using phantom, crosstalk increases by 16-50%. Using the lowest possible energies of X-ray, decreases the crosstalk up to 43% of its initial amount. Furthermore coating a 10 or 20 µm layer of tungsten or lead on the detector separators, decreases the X-ray crosstalk significantly. Conclusion: Choosing the proper high voltage, detectors’ material and its dimensions, scintillator impurities and septa material can decrease X-ray crosstalk.

نویسندگان

zahra kavousi

Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran

Alireza Karimian

Department of Biomedical Engineering - Faculty of Engineering- University of Isfahan

Iraj Jabbari

Department of nuclear Engineering, Faculty of new science and technologies, University of Isfahan, Isfahan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :