Distraction Osteogenesis in Oral and Maxillofacial Reconstruction Applications: Feasibility Study of Design and Development of an Automatic Continuous Distractor
محل انتشار: هفتمین همایش مهندسی برق مجلسی
سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 490
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NCEEM07_062
تاریخ نمایه سازی: 23 آذر 1397
چکیده مقاله:
Distraction Osteogenesis (DO) is one of novel techniques widely used in bone Reconstruction Applications (RA). Recently, DO method has got an important role in oral and maxillofacial RA; by using DO bone defects and skeletal deformities in different cranio-maxillofacial areas can be reconstructed, with better results and reduced effects in comparison to conventional methods. In DO by using a tension-stress principle, mechanical stimulations induce bone generation and biological responses of the tissue. A DO procedure starts with bone osteotomy and implementation of distractor, before proceeding with distraction, there is a latency period which allows the callus to form initially. In the distraction phase, the generated external force goes through the moving bone segment and gradually distract the callus. After distraction phase, there is a consolidation phase and then the device is removed. Most of current DO methods are applied by manual devices; low accuracy and reliability, discontinuous force, manually-operated, and associated problems for patient are major disadvantages of manual devices. Recent studies have revealed using an automatic continuous distractor could significantly improve the DO results while decreasing the existing problems. The purpose of this study is to design and simulate a novel automatic continuous distractor to be used in DO applications. The device contains mini stepper motor and gear-box, controller, mechatronic system, LCD, and keypad. Design’s specification and simulations results show this device has the capability to generate a continuous distraction force for a successful automatic DO.
کلیدواژه ها:
نویسندگان
Katayoun Hatefi
Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran
Shahrokh Hatefi
Department of Mechatronics Engineering, Nelson Mandela University, Port Elizabeth, South Africa
Milad Etemadi sh
Department of Oral and Maxillofacial Surgery, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran