Investigation and Presentation of a Non-destructive Test Method in Electrofusion joints of Polyethylene Gas Piping for City Gas Network
محل انتشار: کنفرانس دو سالانه بین المللی مکانیک جامدات تجربی
سال انتشار: 1396
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 471
متن کامل این مقاله منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل مقاله (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
WMECH04_053
تاریخ نمایه سازی: 11 خرداد 1397
چکیده مقاله:
Thousands of kilometers of polyethylene piping have joints, and the joint is the weak point that should beinspected before the pipe begins service in terms of their safety and economic importance. Electrofusion joints is asuitable method for making polyethylene pipelines. The resistance of the Electrofusion depends on many factors, suchas temperature, pressure at the welding surface, the control of the heating time, ….To achieve the rate of failure close to zero, nondestructive testing (NDT) is strongly recommended in addition to joiningprocess control. This paper introduces a promising NDT method for Electrofusion (EF) joining of PE pipe. For theNDT of the PE pipe EF joining in this study, an ultrasonic real time system and array transducers were developed.Ultrasound is transmitted very well when the EF joint is good. Imperfect fusion joints reflect ultrasound and the fusioninterface will be detected in UT images. In basic experiments a battery operated ultrasonic array system that is namedAIM33 (made in Korea) was used. Geometrical information of the fusion joints such as thickness, wire location, wiregap, fusion length, and cold zone are also identified and measured. Defects such as void, imperfect fusion interface,inclusions, and wire locations are detected. The results of destructive and non-destructive tests are compared for 29samples. The results of the 27 samples were matched in two ways. Obtained results show that NDT testing andmonitoring is reliable and precise.Keywords- ElectroFusion joint, Non-destructive
کلیدواژه ها:
نویسندگان
M Shojaei
Head of Department Identification and Evaluation of Polymer Materials, RIPI, NIOC, Iran
A Bayati
Undergraduate Student of Mechanical Engineering, University of Science and Technology, Tehran, Iran
F Kashefi
Undergraduate Student of Mechanical Engineering, University of Science and Technology, Tehran, Iran