THE EFFECT OF ELECTROCHEMICAL PARAMETERS ON CORROSION RESPONSE OF HYDROXYAPATTE COATING ON AZ31 MAGNESUM ALLOY
سال انتشار: 1390
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 421
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
UFGNSM03_138
تاریخ نمایه سازی: 10 تیر 1396
چکیده مقاله:
Magnesium and its alloys are good candidates as body implant mainly for their mechanical strength and biodegradability. But their weak corrosion behavior can cause sudden failure of implants. In order to control corrosion resistance and biocompatibility of the alloys, hydroxyapatite coating is applied on AZ31 magnesium alloy. Electrodeposition was used to apply the coating at different potentials to optimize its properties, Microstructure and corrosion behavior of the coated samples were compared using scanning electron microscopy (SEM) and electrochemical tests respectively. The results shown that there is an optimum voltage and temperature at which HA coating is totally homogeneous and its corrosion behavior is improved.
کلیدواژه ها:
نویسندگان
M. SAREMI
School of Metallurgy & Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran
E. MIRTAHERI
School of Metallurgy & Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran