Investigating the Effect of Applying Polypropylene Fiber on Compressive Strength of Self-consolidating Concrete

سال انتشار: 1395
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 519

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ICESCON03_355

تاریخ نمایه سازی: 16 شهریور 1395

چکیده مقاله:

Mechanical characteristics of fiber concrete is affected by type, percentage, length to diameter ration, context resistance, size and shape of fiber, sample preparing method and size and shape of sand material. Therefore, in order to use in each case, mix design should be prepared and it must be tested. The current research have been designed and conducted in order to examine the effect of applying propylene fiber on pressure behavior of Self- consolidating concrete. Washed sand with fineness modulus of 3.19 was used in order to prepare experimental samples. The sand which was used in self-consolidating concrete was of broken sand with maximum diameter of 10 millimeter and specific gravity of 2.68. Portland cement type II made by Mazandaran (Neka) Cement Factory was used in this research. Density of the mentioned cement was 3.15. In this research, Limestone powder with density of 2.7 and specific weight of 480 kg/m2 was used as filler element. Mix design that was applied in order to prepare self-consolidating concrete in this study was according to ACI R-07237. In order to measure compressive strength of hardened concrete, cubic samples of 10*10 centimeters were used (B.S 1881: Part 117). Compressive strength test using 10*10 cubic samples in days 7 and 28 was conducted. The results of this research showed that addition of fibers to self-consolidating concrete reduces its compressive strength. Also, it can be concluded from the results obtained from compressive strength test that percentage of fiber in concrete varies inversely with compressive strength, namely, increase of fiber percentage results in reduction of concrete compressive strength

نویسندگان

Moein Roohi

MSc - Civil Engineering, Babol Nooshirvani University of Technology, Iran,

B. Navayineya

Associate Professor of Civil Engineering Faculty, Babol Nooshirvani University of Technology, Iran,

M.H.A. Beygi

Assistant Professor of Civil Engineering Faculty, Babol Nooshirvani University of Technology & Chancellor of Rahedanesh Higher Education Institute, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • ACI committee. (1988). 544 Report: Design Consideration for SFRC. ACI ...
  • Anonymous. (2005). Measuremet of properties of fresh S elf-c ompacting ...
  • Khaloo A. R. And Kim N., (1996). Mechanical Properties of ...
  • Khaloo, A. R. (1992). Mechanical characteristics and application of fiber-armed ...
  • Khaloo, A. R. (1997). Investigation of behavior of mortar armed ...
  • Khaloo, A. R., Bayat-Makoo, K. (1990). Characteri stics of concrete ...
  • نمایش کامل مراجع