Towards Automated Prenatal Care: Attention-Based Deep Learning for Fetal Head Circumference Measurement
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 22، شماره: 6
سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 50
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-22-6_006
تاریخ نمایه سازی: 21 اسفند 1404
چکیده مقاله:
Introduction: Accurate fetal head circumference (HC) estimation from ultrasound images is critical for prenatal assessment, yet current deep learning approaches are limited by scarce annotated training data and inherently low image contrast. These limitations compromise the model's capacity to reliably delineate fetal head boundaries from surrounding uterine structures, directly impacting clinical utility. Material and Methods: This study introduces an attention-based deep learning framework designed to optimize feature extraction by selectively emphasizing diagnostically relevant regions within ultrasound images. The attention mechanism guides the network to prioritize fetal head boundaries while suppressing irrelevant background information, thereby enhancing segmentation precision and feature discrimination during training. Results: Comprehensive evaluation on benchmark ultrasound datasets validates the clinical effectiveness of our approach. The proposed attention-based model achieves a ۲% improvement in fetal head detection accuracy compared to current state-of-the-art methods, while simultaneously reducing overfitting probability by ۵۰%. These gains translate to more robust and reliable HC measurements across diverse imaging conditions. Conclusion: Integration of attention mechanisms into deep neural networks substantially advances automated fetal biometry by addressing two critical challenges: measurement accuracy and model generalization. The demonstrated improvements in both detection performance and overfitting mitigation establish attention-guided learning as a viable pathway toward clinically deployable ultrasound analysis systems, with potential to enhance prenatal care quality and consistency.
کلیدواژه ها:
نویسندگان
Seyed Vahab Shojaedini
Electrical Engineering Department, Iranian Research Organization for Science and Technology, Tehran, Iran
Mohammad Momenian
Computer Engineering Department, E-Campus branch, Azad University, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :