Assessment of Dose Calculation Accuracy of Monaco Treatment Planning System for Effective Wedge Angle in Internal Wedged Fields using Two Different Analytical Methods
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 15، شماره: 1
سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 137
فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-15-1_005
تاریخ نمایه سازی: 14 بهمن 1403
چکیده مقاله:
Background: In radiotherapy, the accuracy of dose calculation systems plays a key role in the treatment of cancer patients.Objective: The current research aimed to evaluate the dose calculation accuracy of Monaco Treatment Planning System (TPS) in estimating the Effective Wedge Angle (EWA) using two different mathematical methods: Elekta formula and ICRU-۲۴ formula.Material and Methods: In this experimental study, EWAs for different field sizes (۵×۵, ۱۰×۱۰, ۱۵×۱۵, ۲۰×۲۰, ۲۵×۲۵, and ۳۰×۳۰ cm۲) at standard angles (۱۵°, ۳۰°, ۴۵°, and ۶۰°) were computed by the Monaco TPS using two different analytical methods. The practical EWAs were measured according to the conditions outlined in the Elekta formula and the ICRU-۲۴ formula, and these measurements were compared with the results derived from the TPS.Results: The planned and measured EWAs are consistent with the Elekta formula, and the error value was less than ±۰.۵ in all radiation fields and EWAs. In the ICRU-۲۴ formula, the maximum deviation was ±۲.۶° between the computational and practical EWAs. Conclusion: The Elekta-based analytical method demonstrates a good agreement between planned and measured EWAs, while the ICRU-۲۴ formula exhibited the greatest discrepancies.
کلیدواژه ها:
نویسندگان
Ali Bahari
Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
Seyed Salman Zakariaee
Department of Medical Physics, Faculty of Paramedical Sciences, Ilam University of Medical Sciences, Ilam, Iran
Hamed Rezaeejam
Department of Radiology Technology, School of Paramedical Sciences, Zanjan University of Medical Sciences, Zanjan, Iran
Ali Tarighatnia
Department of Medical Physics, School of Medicine, Ardabil University of Medical Sciences, Ardabil, Iran
Mikaeil Molazadeh
Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :