Assessment of Mandibular Kinematic Variables using a Motion Analysis System and a Regular Mobile Phone
محل انتشار: مجله فیزیک و مهندسی پزشکی، دوره: 15، شماره: 1
سال انتشار: 1404
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 12
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-15-1_007
تاریخ نمایه سازی: 14 بهمن 1403
چکیده مقاله:
Background: The development of a standard motion capture system is needed since the measurement of temporomandibular disorders is time-consuming and costly using laboratory tools.Objective: The current study aimed to investigate the mandibular kinematic variables using a regular mobile phone and the motion analysis system.Material and Methods: In this quasi-laboratory and comparative study, ten healthy individuals participated, and three mobile cameras, nine red markers, and Kinovea software were also used to investigate the mandibular kinematic variables. Nine light reflective markers were used to check the sensitivity, accuracy, and reliability of the proposed system. The motion was analyzed using seven motion analysis infrared cameras and Qualisys Track Manager (QTM) software. Two other raters analyzed the kinematic variables obtained from the mobile to measure intra- and inter-rater reliability.Results: Pearson’s correlation coefficient was obtained at ۰.۹۸, ۰.۷۵, ۰.۹۸, and ۰.۹۶, showing a high correlation. The accuracy and reliability validation tests showed an average error and an accuracy of ۰.۱۵۶ mm and ۹۵%, respectively, with a mobile phone. The Intra Class Correlation coefficient showed a high internal correlation in the mentioned confidence interval (۰.۹۸ and ۰.۸۱, and ۰.۹۶ and ۰.۹۷). The intraclass correlation coefficient method also showed ۹۷% inter-raster reliability. Conclusion: Mobile phones as a new system can evaluate the kinematic variables of mandibular disorders with appropriate accuracy and reliability.
کلیدواژه ها:
نویسندگان
Mansureh Ziaiee
Department of Sport Biomechanics and Injuries, Faculty of Physical Education and Sports Sciences, Kharazmi University Tehran, Iran
Heydar Sadeghi
Department of Sport Biomechanics and Injuries, Faculty of Physical Education and Sports Sciences, Kharazmi University Tehran, Iran
Mohammad Taghi Karimi
Rehabilitation Sciences Research Center, Shiraz University of Medical Sciences Shiraz, Iran
Masoud Rafiaei
Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Isfahan University of Medical Sciences, Isfahan, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :