A parametric analysis of a bi-directional tuned liquid columndamper
سال انتشار: 1403
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 296
فایل این مقاله در 26 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
STCONF07_005
تاریخ نمایه سازی: 20 مرداد 1403
چکیده مقاله:
In this study, a numerical model for the numerical modelling of a bi-directional tuned liquid columndamper has been developed. Since a viscous fluid is considered for this purpose, the governing equationsare the Navier-Stokes equations. For modelling, OpenFOAM software is utilized. The output of themodel is chosen to be the moment that is applied to the tank body as a result of the pitch moving atvarious amplitudes and periods. Following the model's validation, a sensitivity analysis was conductedon the geometrical parameters of the bi-directional tuned liquid column damper and water level, and thefindings were presented. As a final step, a curve fitting was performed to estimate the maximum momentcaused by the sloshing impact on the bi-directional tuned liquid column damper.
کلیدواژه ها:
نویسندگان
Hassan Saghi
Department of Civil, Environmental & Architectural Engineering, Korea University, Republic of Korea
Goangseup Zi
Department of Civil Engineering, Hakim Sabzevari University, Sabzevar, Iran