Evaluating the local skin temperature under non-uniform and asymmetric environmental conditions- IMTB model

سال انتشار: 1403
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 225

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ISME32_286

تاریخ نمایه سازی: 15 تیر 1403

چکیده مقاله:

Non-uniformity in environmental conditions can affect the occupants’ satisfaction. However, under non-uniform conditions, overall thermal comfort depends on local thermal sensation. This complexity has led researchers to develop several multi-segmental models to predict the local temperature and thermal sensation. The multi-segmental and individualized thermoregulatory bioheat (IMTB) is one of these models. The IMTB is a multi-segmental model dividing body into ۱۷ segments. Additionally, the IMTB model can evaluate the effects of individual parameters (such as height, weight, gender, and age) on physiological parameters and active/passive systems. In this paper, the performance of the IMTB model in estimating local skin temperature in non-uniform environments was assessed. The results indicated that the new model agreed well with empirical data and the average mean absolute error of local skin temperature (MAE) was ۰.۲۷ and ۰.۵۱℃ under steady-state and transient conditions, respectively.

نویسندگان

Mahdi Afzalian

Postdoctoral fellow, University of Birjand, Birjand

Seyed Alireza Zolfaghari

Associate Professor in Mechanical Engineering, University of Birjand, Birjand

Roya Rateghi

Master of mechanical engineering, University of Birjand, Birjand