Quantification the dosimetric parameters of asymmetric physical wedged-۶MV photon beam

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 79

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-0_091

تاریخ نمایه سازی: 29 آذر 1402

چکیده مقاله:

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the parameters for asymmetric wedged fields become necessary. The study aims to achieve output factors and dose profiles for symmetric and asymmetric wedged fields of ۶ MV photon beams. Materials and Methods: The Siemens PRIMUS Linac head for ۶ MV photon beam was simulated by BEAMnrc and all dose calculations were performed by DOSXYZnrc code. Percentage depth dose (PDD) and profiles for open and wedged (۱۵° and ۴۵°) fields were compared with corresponding measurements. Wedge factors for ۱۰ x ۱۰ cm۲ field size as a function of lateral distance from central axis were obtained as well for half beam (negative or positive Y jaws were closed) wedged fields. All mesurments were carried out using ۰.۱۲۵ cm۳ Farmer type ionization chamber with DOSE۱ electrometer (FC۶۵G, Scanditronix-Wellhofer, Germany) at the depth of ۱۰ cm with source to surface distance (SSD) of ۱۰۰ cm in ۵۰ cm۳ PTW-Blue water phantom and processed by dosimetry software RFAplus (Version ۵.۲, Scanditronix-Wellhofer, Germany). Results: The calculated doses were in agreement with measured data that confirmed the simulated MC model. The output factors on the central axis of symmetric wedged beams decreased to ۰.۶۹۳ and ۰.۳۰۷ for ۱۵˚ and ۴۵˚ wedges, respectively. The total photon fluence of ۱۵˚ and ۴۵˚ physical wedged fields reduced to ۷۱.۶% and ۲۷.۷% of fluence for open field, respectively. It was found that the output factor for asymmetric wedged fields is lower than ones from symmetric fields, particularly at field edges. Conclusion: The presences of physical wedge across the beamline decrease the photon fluence and cases beam hardening both for symmetric and asymmetric wedged fields. Lack of scattering photons near the half beam edges in asymmetric wedged field causes a dose fall off in these regions where have potential to overestimate the calculated dose by treatment planning system and consequent cold spots at target volume. Our calculated correction coefficients are recommended to calculate doses by TPS in case of asymmetric wedged fields.

نویسندگان

Mansour Zabihzadeh

Associate Professor, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Associate Professor, Department of Clinical Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapur

Seyed Mohammad Hoseini

Associate Professor, Department of Clinical Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Sholeh Arvandi

Assistant Professor, Department of Clinical Oncology, Faculty of Medicine, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Mojtaba Hoseini- Ghahfarokhi

PhD student, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

hamideh mazraeh

MSc of Medical Physics, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Farnaz Rahimli

MSc of Medical Physics, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Mahbube Fadaei

MSc of Medical Physics, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.