Determination of therapeutic standard field for cancer patients including the medical megavoltage accelerator jaws movement.

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 86

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-0_339

تاریخ نمایه سازی: 29 آذر 1402

چکیده مقاله:

Introduction: Accurate calculation of equal square field size is important in radiation therapy and A factor, in the Vadash formula must be determine by considering collimator exchange effect. Therefore, the purpose of this study was to determine the best A factor, for calculation of equal square field size in treatment planning   Materials and Methods: A new simple protocol method based on the selection of best dosimetric data was proposed to obtain A value in Vadash relation to predict the equivalent square field size, which compensates collimator exchange effect in output factors in air (OFair). Measurements performed with Farmer chamber ۰.۶ cc in SSD ۱۰۰cm and build up cap of Plexiglas, ۱.۵ and ۳.۵ cm equals water, for ۶ and ۱۸ MV, respectively on a Perimus Plus linear accelerator. OFair measured for square and rectangular fields. MATLAB software (version R۲۰۱۴a) was used to calculations and curve fitting. Results: Power model with constant value applied to OFair as a function of square field size. OFair ranged from ۰.۹۸۳ to ۱.۰۳۸ in ۶MV and from ۰.۷۳۱ to ۱.۰۵ in ۱۸ MV and Y collimator had a greater effect on the OFair. The values of ۱.۴۲ and ۱.۵۵ were selected for "A" in ۶ and ۱۸ MV, respectively. Conclusion: The proposed A values minimize the collimator exchange effect, in calculating the equivalent squares which plays an important role in the patient dose calculation and treatment planning. The value of A should be calculated for each machine and energy.

کلیدواژه ها:

equal square field size ، collimator exchange effect ، Vadash formula ، Output factors in air

نویسندگان

Mohammad Javad Tahmasebi Birgani

Professor of Radiotherapy and Oncology, Department of Radiotherapy and Oncology, Golestan Hospital, Ahvaz Jndishapur University of Medical Sciences, Ahvaz, Iran.

Nahid Chegeni

Assistant Professor of Medical Physics. Department of Medical Physics, Medical School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Raziye Fayazi

Msc students of medical physics, Department of Medical Physics, Medical School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Marziyeh Tahmasbi

Assistant Professor of Medical Physics. Department of Radiology Technology, Jundishapur University of Medical Sciences, Ahvaz, Iran

Jafar Fatahi Asl

Assistant Professor of Medical Physics. Department of Radiology Technology, Jundishapur University of Medical Sciences, Ahvaz, Iran

Mohammad.Ali Behrooz

Professor of Radiotherapy and Oncology, Department of Radiotherapy and Oncology, Golestan Hospital, Ahvaz Jndishapur University of Medical Sciences, Ahvaz, Iran.