An iterative method to estimate x-ray attenuation coefficients in computed tomography

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 64

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-15-0_341

تاریخ نمایه سازی: 29 آذر 1402

چکیده مقاله:

Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (DECT), determination of electron density and dose calculation in treatment planning system. The aim of this paper is to calibrate the CT system, to calculate Compton scattering and photoelectric effect by an iterative method. Materials and Methods: Chemical compounds with known effective atomic number and electron density were scanned at ۸۰, ۱۱۰, and ۱۳۰kVp. HU values of these compounds were used to calculate Compton scattering and photoelectric effect by an iterative method. The calculated coefficients were used to estimate the HU values of liquid samples and solid rods made of polymers, to evaluate our findings Results: The coefficients were found up to the fifth order of iteration and the coefficients were found to match the data with ۹۵% confidence at ۸۰, ۱۱۰, and ۱۳۰ kVp. The maximum deviation between the calculated and actual HU values were less than ۳% for liquid and solid samples at these kVp values. Conclusion: Calibration of CT system by known chemical samples, by using iterative method of data analysis may give very accurate idea about the x-ray attenuation coefficients of samples. Results of this study may be used in tissue characterization by DECT inversion, and to estimate electron density and dose distribution in treatment planning systems

نویسندگان

Rezvan Ravanfar Haghighi

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Somayeh Gholami Bardeji

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Mahdi Dodangeh

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

S. Chatterjee

Ongil, ۷۹ D۳, Sivaya Nagar, Reddiyur Alagapuram, Salem ۶۳۶۰۰۴, India

Ali Reza Shakibafard

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Reza Jalli

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Sepideh Sefidbkht

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Fariba Zarei

Medical imaging Research Centre, Shiraz University of Medical Sciences, Shiraz ۷۱۹۳۶۳۵۸۹۹, Iran

Vani VC

Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore ۵۶۰۰۱۲. India