Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 160
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JOAPE-6-1_004
تاریخ نمایه سازی: 13 آبان 1402
چکیده مقاله:
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush currents, can cause the windings to be deform, rupture, and/or displace, if the transformer and winding holders structure is not designed or assembled properly. Also, these mechanical changes can damage insulation between two or more adjacent turns of a winding and so, produce the local inter-turn fault. Occurrence of any fault in windings will change the electromagnetic force distribution in transformers and will cause developing secondary faults. Hence, this contribution is aimed at characterizing the electromagnetic forces behavior in power transformers and determines the changes of force values after occurring winding mechanical and inter-turn. The study keeps at disposal a two-winding, three phase, ۸ MVA power transformer, on their windings faults are imposed and investigated through the FEM analysis. The accuracy of the created FEM model is firstly validated using analytical methods for transformer healthy condition, and then the winding shorted turn fault along with the mechanical faults are considered using ۳D FEM model. The extracted characteristic signatures attained to different type of winding faults is expected to be useful at the design stage of power transformers.
کلیدواژه ها:
ترانسفورماتور قدرت ، نیروهای الکترومغناطیسی ، روش اجزاء محدود ، خطاهای مکانیکی سیم پیچی ، خطای اتصال کوتاه حلقه
نویسندگان
V. Behjat
Department of Electrical Engineering, Azarbaijan Shahid Madani university, Tabriz, Iran. Email: behjat@azaruniv.edu
A. Shams
Department of Electrical Engineering, Engineering Faculty, Azarbaijan Shahid Madani University, Tabriz, Iran
V. Tamjidi
Department of Electrical Engineering, Engineering Faculty, Shahid Madani University, Tabriz, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :