Investigation of Increasing Accuracy Distributed Voltage on the Power Transformer Disks Considering Mutual Induction and Different Grounding System Models
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 117
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JOAPE-10-3_008
تاریخ نمایه سازی: 13 آبان 1402
چکیده مقاله:
Power equipment are subjected to multiple shock voltages during their operations that are generally caused by a lightning strike, switching of electronic power devices, or transient voltages which across available in the power system. These impulses have a frequency range from several kHz to several MHz, which take pulses at very short intervals in several microseconds. Also, the equipment experiences the peak voltage and subsequently peak currents than their nominal values. These variations in voltage and current values, in very short intervals, have destructive effects on these equipment insulated systems as well as on the accuracy of measuring ground impedance. The primary purpose of this study is to investigate the effect of standard and non-standard voltage impulse on power transformers windings by considering the mutual induction of transformer windings. Furthermore In this paper, by applying lightning pulse on power transformer windings for different models of ground voltage distribution system on different disks of transformer windings terminal (۲۰/۰.۴KV, ۱۰۰KVA, ۹ disks continuous winding) and the disks voltage are calculated as outputs in MATLAB/Simulink. In previous studies, the calculations were in the time domain, while in this study, the ground impedance was measured in the frequency domain. The simulation results show that considering the model RC and considering the mutual induction, the voltage distribution on the disks is higher than other models. This study provides functional information for improving the design of insulations that are installed between windings and core the results of the present research may lead to the minimization of the dielectric failures. Furthermore, the results of this study can be used in future studies about non-standard impulse voltages. This investigation can certainly lead to modifying available standards or creating new standards in power transformers.
نویسندگان
M. Talebzadeh
Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran
A. Setayeshmehr
گروه برق، واحد دزفول، دانشگاه آزاد اسلامی، دزفول، ایران
H. Barati
عضو هیات علمی / دانشگاه آزاد اسلامی واحد دزفول
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :