چکیده مقاله:

In this paper an attempt is made to review the specific urease with one of the best and most modern materials, modifiers, in order that multi-walled carbon nanotubes (MWCNTs) / silica, which has been modified with the rest of the Biosensors are a large variety of electrodes with different genera based fixative that can work with different fixed times to examine. This is important in order to be useful for biosensor And a lot of them, sometimes we doubt that what we wrong Biosensor that is relevant to our work, we use this to help us Associated with plant conditions and at what strength and durability of stabilized We expect our biosensor, Biosensors of your choice to be taken to maximize the efficiency of its And have less time and money trying to be good and resist. The resulting biosensor exhibits a good response performance to urea detection with a wide linear range from 2.18×10−5 to 1.07×10−3 M urea. The biosensor shows a short response time of 10–25 s and a high sensitivity of 23 mV /decade/ cm2 [

نویسندگان

Bahram Niazmand

Department of petroleum engineering, Islamic Azad University, Shahrood Branch , Shahrood , Iran

Afshin Farahbakhsh

Department of petroleum engineering, Islamic Azad University, Quchan , Quchan , Iran

Pouyan Foroughy Zadeh

Department of petroleum engineering, Islamic Azad University, Gachsaran Branch, Gachsaran, Iran

Mostafa Eghbaly

Department of petroleum engineering, Islamic Azad University, Shahrood Branch, Shahrood, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • T. Ahuja, D. Kumar, N. Singh, A.M. Biradar, Rajesh, Materials ...
  • L. Della Ciana, G. Caputo, Clin. Chem. 42 (1996) 1079-1085. ...
  • B. Xie, M. Mecklenburg, B. Danielsson, O. Ohman, P. Nolin, ...
  • B. Xie, _ Danielsson, Anal. Lett. 29 (1996) 1921. ...
  • Rajesh, V. Bisht, W. Takashima, K. Kaneto, React. Funct. Polym. ...
  • T.Ahuja, I.A. Mir, D.Kumar, Rajesh, Sens.Actuators, B 134 (2008) 140. ...
  • I. Gill, Chem. Mater. 13 (2001) 3404. ...
  • K. B a lasubramanian, M. Burghard, Anal. Bioanal. Che. 385 ...
  • M. Paradise, T. Goswami, Mater. Des. 28 (2007) 1477. ...
  • J. Huang, Z. Song, J. Li, Y. Yang, H. Shi, ...
  • W.J. Cho, H.J. Huang, Anal. Chem. 70 (1998) 3946. ...
  • G.G. Guilbault, J. Montalvo, A urea specific enzyme electrode, J. ...
  • G.G. Guilbault, E. Hrabankova, Anal. Chem. 42 (1970) 1779. ...
  • C. Eggenstein, M. Borchardt, C. Diekmann, B. Grundig, C. Dumschat, ...
  • T. Anfalt, A. Graneli, D. Jagner, Anal. Lett. 6 (1973) ...
  • G.G. Guilbault, F.R. Shu, Enzyme electrodes based on the use ...
  • J. Mu noz, C. Jimenez, A. Bratov, J. Bartroli, S. ...
  • M. Mascini, Potentiometry: enzyme electrodes, in: A. Townsheand (Ed.), Encyclopedia ...
  • R. Gupta, N.K. Chaudhury, Biosens. Bioelectron. 22 (2007) 2387. ...
  • I. Gill, Chem. Mater. 13 (2001) 3404. ...
  • Academic, London, 1995, p. 4112. ...
  • K. Sawickaa, P. Goumab, S. Simonc, Sens. Actuators B 108 ...
  • W.-J. Kim, S.-O. Kang, C.S. Ah, Y.-W. Lee, D.H. Ha, ...
  • K. Itoh, C. Ohe, T. Tsurumaru, S. Yasukawa, T. Yamaguchi, ...
  • C. Zhao, L. Ji, H. Liu, G. Hu, S. Zhang, ...
  • H. Yu, C. Lu, T. Xi, L. Luo, J. Ning, ...
  • _ Kovacs, G. Nagy, R. Dombi, K. Toth, Biosens. Bioelectron. ...
  • I. Vostiar, J. Tkac, E. Sturdik, P. Gemeiner, B i ...
  • K. Sawickaa, P. Goumab, S. Simonc, Sens. Actuators B 108 ...
  • [G. Dhawan, Biochemical Engineering Journal 44 (2009) 42-52] ...
  • A.M. Kayastha, N. Das, Biochem. Educ. 27 (1999) 114-117. ...
  • F. Kuralay, H. Ozyoruk, A. Yy ldy z, Sens. Actuators ...
  • S. de Marcos, R. Hortigiiela, J. Galbfin, J.R. Castillo, O.S. ...
  • S.B. Adeloju, S.J. Shaw, G.G.Wallace, Anal. Chim. Acta 28 (1993) ...
  • Rajesh, V. Bisht, W. Takashima, K. Kaneto, Surf. Coat. Technol ...
  • R.Singhal, A.Gambhir, M.K. Pandey, S. Anapoorni, B.D. Malhotra, Biosens. Bioelectron. ...
  • Y. Hou, N.J.Renault, A. Zhang, J.Wan, A. Errachid, J.M.Chovelon, Sens.Actuatos ...
  • S. Arisawa, R. Yamamoto, Thin Solid Films 210 (1992) 443-445. ...
  • W.Y. Lee, S.R. Kim, T.H. Kim, K.S. Lee, M.C. Shin, ...
  • نمایش کامل مراجع