The effect of using RBS connection on the distribution of plastic strain energy in steel structures

سال انتشار: 1402
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 262

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

این مقاله در بخشهای موضوعی زیر دسته بندی شده است:

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

CAUICNF08_048

تاریخ نمایه سازی: 9 شهریور 1402

چکیده مقاله:

Many connections are used in steel structures. A connection with a reduced cross-section is one of them. Limiting the plastic moment, this connection makes the columns bear less moment. Using a connection with a reduced section makes the structure this guarantee that the fuse is formed in the reduced area and the column element can play a role as a force-control member. In this research, it has been tried to evaluate the effect of using RBS connections in five and ten-story steel structures. The purpose of this research is to evaluate the effect of using a connection with a reduced cross-section in the distribution of strain energy in the structure. After designing, the structures are modeled non-linearly in perform-۳d software and then analyzed under near-field records. The results have shown that the contribution of strain energy wasted in beams with reduced cross-section connections is more than in structures without this connection, which has caused the rotation in columns to decrease.

نویسندگان

Seyed Milad Hasheminejad

MSc, Earthquake Engineering, Babol University of Technology

Majid Moradi

PhD, Earthquake Engineering, Babol University of Technology

Hossein Najafi

Master of urban management, technical expert of Sari Municipality