Measurement of Glutamate Neurotransmitter in the Brain of Male Rat Using Glutamate Oxidase-Based Electrochemical Biosensor
سال انتشار: 1402
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 92
فایل این مقاله در 11 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_SHIMU-31-2_006
تاریخ نمایه سازی: 28 خرداد 1402
چکیده مقاله:
Introduction: Glutamate oxidase (GluOx; EC ۱.۴.۳.۱۱), as an oxidoreductase enzyme, catalyzes the oxidation of glutamate to α-ketoglutarate, ammonia, and hydrogen peroxide (H۲O۲). In this reaction, the amount of H۲O۲ is proportional to the concentration of glutamate and its concentration can be measured by using an electrochemical biosensor. The same as other enzyme-based biosensors, glutamate oxidase is one of the key elements in the construction of glutamate biosensors. Such biosensors are fully capable of identifying biological analytes, such as glutamine, ammonia, and creatinine. In addition, glutamate oxidase-based biosensors have many applications in quantitative and qualitative measurements in analytical chemistry, determining the quality of food products, as well as early detection of heart and liver disorders in clinical biochemistry. Considering the importance of the glutamate neurotransmitter in various brain functions, this study investigated its measurement in the brain of male Wistar rats by using a glutamate oxidase-based biosensor.
Material & Methods: In order to measure glutamate, initially, a glutamate oxidase-based biosensor was made by simultaneously immobilizing the enzyme and chitosan on the platinum electrode surface. Then, the animals were sacrificed, and their brains were removed and placed in a phosphate buffer. Afterward, the contents of the brain were centrifuged to create a completely uniform mixture. Finally, the concentration of glutamate in the prepared brain samples was measured using the fabricated biosensor by the cyclic voltammetry technique.
Findings: The results of cyclic voltammetry experiments showed that the cathodic peak current of the fabricated biosensor was ۰.۸۱۲ µA. Moreover, the calibration curve indicated that the biosensor response was linear up to ۱ mM and glutamate concentration in brain samples was also equal to ۶۳.۵ µM.
Discussion & Conclusion: The cyclic voltammetry experiments showed that the concentration of H۲O۲, which is produced during the catalytic activity of glutamate oxidase, is completely proportional to the concentration of glutamate oxidase. Furthermore, this study showed that, despite the very low concentration of glutamate neurotransmitters, the glutamate oxidase-based electrochemical biosensor can precisely identify it qualitatively and quantitatively in biological samples, such as brain samples.
کلیدواژه ها:
Chitosan ، Cyclic voltammetry ، Electrochemical biosensor ، Glutamate oxidase ، Glutamate ، گلوتامات ، گلوتامات اکسیداز ، زیست حسگر الکتروشیمیایی ، ولتا متری چرخه ای ، چیتوسان
نویسندگان
فائزه فرجی
Dept of Biology, Science and Research Branch, Islamic Azad University, Tehran, Iran
حسن توکلی
Radiation Injuries Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
مهوش جعفری
Dept of Biochemistry, Faculty of Medicine, Baqiyatallah University of Medical Sciences, Tehran, Iran
اکرم عیدی
Dept of Biology, Science and Research Branch, Islamic Azad University, Tehran, Iran
عادله دیوسالار
Dept of Cell and Molecular Sciences, Faculty of Biological Sciences, Kharazmi University, Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :