Night flow analysis and MNF calculation in the subarea of Phase ۲ of Mehrgan town, Mashhad, Iran

سال انتشار: 1401
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 179

فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

CAUCONG02_016

تاریخ نمایه سازی: 19 آذر 1401

چکیده مقاله:

Leakage in urban water distribution networks is a serious problem due to the shortage of water resources, and this has necessitated planning to reduce leakage in water supply networks and facilities down to the economic level. In this study, the minimum night flow analysis method was adopted to estimate the leakage rate of the distribution network of the subarea of the ۵۰۰۰-m۳ tank in Mehrgan town (Phase ۲), Iran. In this method, the amount of night leakage was first obtained by measuring the inlet flow rate to the network for a month during the hours of minimum consumption (۲ to ۴ AM) and deducting the night consumption of the subscribers, and then, by determining the average zone pressure point and analyzing the data at this point, the night-day factor was determined; by multiplying this factor by the amount of night leakage, the average daily leakage was calculated. The results revealed that the amount of daily network leakage is about ۹۸.۴ m۳ per day.

کلیدواژه ها:

نویسندگان

Adel Dadsetan

Ph.D. student of Civil Engineering, Mashhad Water and Wastewater Company – Iran

Babak Amirsardari

MS in Civil Engineering, Mashhad Water and Wastewater Company – Iran

Shadli Zafari

MS in Information Technology, Mashhad Water and Wastewater Company – Iran

Mohammad Reza Fathi

BS in Civil Engineering, Tehran Water and Wastewater Company – Iran