Internal Consistency of Two Testing Modalities for Barbell Velocity and Power During the Back Squat
سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 296
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JJAST-4-1_012
تاریخ نمایه سازی: 2 آبان 1401
چکیده مقاله:
Internal consistency can be defined as the reliability across similar items in a test. Considering the importance of power and velocity during resistance training, it is crucial to have accurate testing methods for quantifying these variables. With recent technological advancements, various devices are increasingly used to quantify barbell velocity and power in the weight room to better understand the exercises prescribed. The purpose of the study was to determine the internal consistency of a novel ۳-D camera system and a commonly used tether-based dynamometer by comparing them to a laboratory-based linear position transducer. To assure a consistent stimulus, one weight-trained male (age = ۲۸ yrs, height = ۱.۷۸ m, mass = ۹۷.۱ kg, ۱RM squat = ۲۲۶.۸ kg) completed ۱۰ sets of ۱ repetition with maximal concentric acceleration at each prescribed load of ۳۰, ۴۰, ۵۰, ۶۰, ۷۰, and ۸۰% of his individual ۱RM, for a total of ۶۰ repetition trials. All devices used in this study collected the data simultaneously. All three methods of measurement exhibited strong correlations (r ≥ ۰.۸۰) while Cronbach alpha values for mean velocity, peak velocity, mean power, and peak power were ۰.۹۹۸, ۰.۹۹۵, ۰.۹۸۱, ۰.۹۵۱, respectively. Bland-Altman plots showed that all four variables were well within ۹۵% limits of agreement. Based on our results, we can conclude that the use of a ۳-D camera system or a tether-based external dynamometer provides measures of barbell velocities and powers consistent with laboratory-derived measures. These findings indicate strength and conditioning professionals can monitor resistance training with any of the systems used and achieve similarly consistent values.
کلیدواژه ها:
نویسندگان
- -
Kansas Team Health: Sports Performance, Kansas Athletics Inc., University of Kansas, Lawrence, KS, USA
- -
Jayhawk Athletic Performance Laboratory, Department of Health, Sport, and Exercise Sciences, University of Kansas, Lawrence, KS, USA
- -
Jayhawk Athletic Performance Laboratory, Department of Health, Sport, and Exercise Sciences, University of Kansas, Lawrence, KS, USA
- -
Department of Exercise and Sport Science, Eastern Kentucky University, Richmond, KY, USA
- -
School of Kinesiology, George Mason University, Manassas, VA, USA