Evaluation of Microleakage of Self-Adhesive Composite Resin in Pits and Fissures of Extracted Premolar Teeth: An in Vitro Study
محل انتشار: فصلنامه زیست پزشکی جرجانی، دوره: 10، شماره: 2
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 131
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JOBJ-10-2_007
تاریخ نمایه سازی: 10 مهر 1401
چکیده مقاله:
Background and objectives: Microleakage at the interface of tooth structure and fissure sealant plays a crucial role in failure of the treatment. This in vitro study aimed to determine the microleakage of self-adhesive flowable composite resins as pit and fissure sealants.
Material and Methods: ۶۰ healthy extracted premolar teeth were randomly divided into the ۴ groups (n=۱۵), group ۱) clinpro sealants (control), group ۲) flowable composite resin with bonding agent (total-etch), group ۳) flowable composite resin with self-etch bonding agent, and group ۴) self-adhesive composite resin. After thermocycling the specimens were immersed in ۲% methylene blue for ۴۸ hours and then sectioned in the buccolingual direction. The microleakage was assessed by dye penetration using a stereomicroscope at ۱۵X magnification. Data analysis was performed using SPSS version ۱۸.۰ as well as Mann-Whitney and Kruskal-Wallis tests.
Results: There was a statistically significant difference in microleakage score between the groups (P-value = ۰.۰۰۶). The lowest mean of microleakage level was observed in the flowable composite group with total-etch bonding (group ۲) ۱.۲۶±۰.۹۶, followed by the Clinpro sealant group (group ۱) ۱.۶۲±۱.۲۰, and then the self-adhesive composite group (group ۴) ۱.۸۵±۱.۰۰.
Conclusion: Based on the results of this study, the microleakage of self-adhesive composite resin revealed no significant difference with conventional fissure sealant; however, the microleakage of these composite resin was higher than flowable composite resin with total-etch bonding agent.
کلیدواژه ها:
نویسندگان
zahra bahrololoomi
Associated Professor, Department of pedodontics, Shahid Sadoughi University of Medical Sciences,Yazd,Iran
fateme mehravar
Assistant Professor, Department of pedodontics, Shahid Sadoughi University of Medical Sciences,Yazd,Iran
niloofar halvani
Assistant Professor, Department of pedodontics, Shahid Sadoughi University of Medical Sciences,Yazd,Iran
hamed saeid
Dentist, Yazd, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :