Design and Construction of a Novel and an Efficient Potentiometric Sensor for Determination of Sodium Ion in Urban Water Samples

سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 207

فایل این مقاله در 21 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_CHM-6-11_008

تاریخ نمایه سازی: 13 شهریور 1401

چکیده مقاله:

Sodium ions are one of the essential cations for various activities in the human body to control fluid levels, blood pressure, and nerve and muscle functions. Sodium-ion is a highly soluble chemical that small amounts of it can be absorbed by the body through water intake. However, consuming an excess amount of sodium ions can cause problems in the body. Therefore, it is vital to measure sodium ions in water samples. A novel and cheap potentiometric sensor was developed to measure trace amounts of sodium ions in real water samples. For the purpose, four effective components in the Nernstian response of the sensor, including ۱-Hexyl-۳-methyl imidazolium hexafluorophosphate as an ionic liquid, ۱, ۴ Diaminoanthraquinone (DAQ) as an ionophore, graphene oxide nanosheets, and paraffin oil as a binder were optimized using a response surface methodology (RSM) based on central composite design. The optimum percentages of paraffin, ionic liquid, ionophore, and graphene oxide to prepare the sensor were ۱۳.۳۴, ۱۱.۴۰, ۳.۲۱, and ۲.۱۶ %, respectively. Under the best percentage of electrode components, the potentiometric sensor showed a suitable slope of ۵۹.۲ mV decade-۱ over a wide Na+ concentration range (۱۰-۶-۱۰-۲ mol L-۱) with a proper detection limit of ۸.۹۷×۱۰-۷ mol L-۱. The sensor can be applied to measure sodium ions in a pH range of ۴ to ۸. The optimized geometry of the complex formed between sodium ion and the ionophore was investigated using the density functional theory (DFT) methods.

کلیدواژه ها:

Sodium-ion Modified sensor Graphene oxide Ionic Liquid ۱ ، ۴ Diaminoanthraquinone Experimental design

نویسندگان

Shiva Ariavand

Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran

Mahmoud Ebrahimi

Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran

Ebrahim Foladi

Department of Food Safety and Quality Control, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :