Use a biomechanical experimental setup to analysis the reliability of force plate postural control parameters in chronic ankle instability patients, copers and healthy control
محل انتشار: مجله مکانیک کاربردی محاسباتی، دوره: 53، شماره: 2
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 166
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JCAM-53-2_003
تاریخ نمایه سازی: 4 تیر 1401
چکیده مقاله:
Ankle sprain is one of the most prevalent joint injury in the lower extremity. Valid and reliable measurement techniques is essential for the collection of accurate and meaningful data about joint injuries such as ankle sprain. We design this case-control study to evaluate the test–retest reliability of force plate measures and compare the static postural control values in in patients with chronic ankle Instability (CAI), ankle sprain copers & healthy controls. Seventy five patients (۲۵ CAI, ۲۵ copers & ۲۵ healthy match controls) were asked to execute single-leg stance onto a force plate. Force plate parameters include, the COP area, COP length, mean total velocity and sway index were measured for static postural control evaluation. To evaluate test–retest reliability, ۲۰ participants of each group repeated the tests ۶–۸ days after the first session. Relative reliability of the force plate measures was assessed using interclass correlation coefficient (ICC) and absolute reliability using standard error of measurement (SEM), minimal metrically detectable change (MMDC) and coefficient of variance percent (CV%). Analysis of variance (ANOVA) was used to determine differences between three groups. Static postural control measures have high test–retest reliability, ranging from ۰.۷۳ to ۰.۸۸. Greater postural sway has been observed in the CAI compared with the coper (P< ۰.۰۵) and the matched limb of the control group (P<۰.۰۵). Static postural control measures are reliable tests to evaluate functional performance of the patients with CAI, copers and healthy controls.
کلیدواژه ها:
نویسندگان
Somayeh Mohamadi
Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
Mahyar Salavati
Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
Amir Salar Jafarpishe
Department of Ergonomics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :