Acoustic waveguides: An attractive alternative for accurate and robust contact thermometry

سال انتشار: 1401
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 82

فایل این مقاله در 7 صفحه با فرمت PDF و WORD قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ICISME02_036

تاریخ نمایه سازی: 31 اردیبهشت 1401

چکیده مقاله:

We report a robust and very precise method of measuring temperature using ultrasonic waves. Solid stainless steel waveguides are used to provide well-defined and stable ultrasonic wave propagation paths. Ultrasonic wave velocity is strongly temperature dependent. The arrival times of the ultrasonic wavepackets along a waveguide are used to infer the average temperature of the waveguide. Our ultrasonic temperature measurements exhibit a high precision (i.e. ±۰.۰۱۵◦C) that is more than two times better than the quoted accuracy of ۱/۱۰ DIN resistance temperature detectors (RTDs). The responsiveness of the waveguides was also investigated. While ultrasonic measurements can be made at very high frequencies, the responsiveness is limited by the heat transfer into the active sensing area. The waveguides make it easy to customise the dimension of the active sensing area and a shorter response time than those of RTDs has been demonstrated. The technique presented in this paper is a robust and cost effective alternative to other contact temperature measurements.

کلیدواژه ها:

Ultrasonic waveTemperatureWaveguidePiezoelectric transducerContact thermometry

نویسندگان