Study on Flow Characteristics of Helium Turboexpander with a Novel Intake Structure
سال انتشار: 1401
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 139
فایل این مقاله در 10 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JAFM-15-3_014
تاریخ نمایه سازی: 18 فروردین 1401
چکیده مقاله:
The cylindrical volute intake structure possesses some advantages including convenient processing, convenient installation & uninstallation and high machining efficiency. The helium turboexpander with this novel intake structure in a superconducting cryogenic device is investigated deeply in this study. Based on the established mathematical model and the corresponding numerical computation methods, the whole flow passage internal flow of the helium turboexpander is numerically simulated. And then the distribution characteristics of total pressure, static pressure, static temperature, relative velocity and total enthalpy in the cylindrical volute, nozzle, impeller and diffuser are explored, and loss mechanism of the internal flow is analyzed. The results indicate that the novel cylindrical volute intake structure has obvious pre-rotation effect on the inlet flow field of the nozzle, and this intake structure has little loss. In addition, the expansion effect in downstream components including nozzle and impeller is obvious, and the flow field changes uniformly. The overall efficiency of the turboexpander is up to ۸۴.۸%, which indicates that it is reasonable that the novel cylindrical volute is used as the intake structure of turboexpander.
کلیدواژه ها:
Helium turboexpander ، Cylindrical volute intake structure ، Numerical simulation ، Flow characteristics
نویسندگان
L. Chen
College of Environmental and Energy Engineering, Beijing University of Technology, Beijing ۱۰۰۱۲۴, China
B. Meng
School of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing ۱۰۲۶۱۷, China
Z. Zhang
School of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing ۱۰۲۶۱۷, China
Y. Xiao
School of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing ۱۰۲۶۱۷, China
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :