Experimental Evaluation of Cyclic Behavior of Concrete Filled Steel Battened Columns
سال انتشار: 1400
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 187
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JSEE-22-2_004
تاریخ نمایه سازی: 15 آبان 1400
چکیده مقاله:
Steel battened columns have been widely used in semi-rigid frames in last decades in some countries including Iran. In past earthquakes, severe failure under lateral actions was observed in residential and industrial buildings with such structural system. Many retrofitting or repairing methods have been proposed including adding some steel plates to the columns in order to change their section to a box. These methods are not only expensive and hard but also did not strengthen the columns at the connection with beams. Therefore, this paper has focused on a new innovative method; filling the battened columns with concrete, which has been previously applied for steel tubes. In this experimental and analytical program on seven specimens, axial load level and batten spacing intervals were considered as the key variables. The obtained results showed that the concrete filled battened columns can provide a stable cyclic response with enhanced lateral strength, higher dissipated energy and ductility, in comparison with the hollow one; the average improvement in the lateral strength and energy dissipation were recorded as about ۳۰% and ۳۰۰%, respectively, in comparison with the hollow ones. Furthermore, it is shown that capacity modification factor of a concrete-filled specimen is up to ۴۷% higher than that of the similar hollow one. Regarding that filling with concrete raises both the ductility and strength. This method is highly recommended to strengthen fragile hollow battened columns.
کلیدواژه ها:
نویسندگان
Mehrdad Zare Dastjerdian
Ph.D. Candidate, Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismology (IIEES), Tehran, Iran
Majid Mohammadi
Associate Professor, Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismology (IIEES), Tehran, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :