Determination of Specific Anatomic Locations by SIFT Algorithm for Locating Cephalometric Points with the Use of an Automatic Technique

سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 238

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_ORTHO-12-2_006

تاریخ نمایه سازی: 12 آبان 1400

چکیده مقاله:

Background Lateral cephalometry is very important for the evaluation of growth, diagnosis, treatment planning and therapeutic evaluations. Considering the advantages of lateral cephalometric analyses with the automatic technique and given the existing problems, the present study was undertaken to use a new automatic technique for determination of cephalometric landmarks. Aim The aim of the present study was to determine the specific anatomic area by SIFT algorithm for locating cephalometric points using an automatic technique. Methods In this study, ۱۱۰ digital lateral cephalograms were randomly selected and pre-processing was carried out on the images. Three orthodontics used these cephalograms to manually select ۱۱ cephalometric landmarks (point A, point B, PNS, ANS, Po, Or, N, Ar, Me, Gn and Pog) on a software program which had been designed to this end. The coordinates of the selected points were saved in the database for the corresponding process of the images. After completing the software program with these data, ۳۰ new radiographs were submitted to the software program for anatomic determination of the points. SIFT algorithm was used in the software program for the anatomic identification of the landmarks. To make a comparison, these ۳۰ cephalograms were manually analyzed by three orthodontists in order to evaluate the accuracy of the software program at various points. Paired t-teat was used to compare the manual and computerized techniques. Statistical significance was set at P < ۰.۰۵. Results Based on the results, the differences between the manual and automatic methods in determining cephalometric landmarks were < ۱ mm in ۴۶% of cases, < ۱.۵ mm in ۸۲% of cases and < ۲ mm in ۱۰۰% of cases. In addition, there were no significant difference between the two method except for points Or, Po and PNS (P > ۰.۰۵). Conclusions It was concluded that the designed algorithm had good performance for easy and relatively difficult points. In relation to very difficult points, too, it exhibited rather acceptable performance and located the points better than other algorithms.

کلیدواژه ها:

نویسندگان

Behnam Mirzakouchaki

Associated Professor, Department of Orthodontics, Tabriz University of Medical Sciences, Tabriz, IR Iran

Reza Faraji

Post-Graduate Student, Department of Orthodontics, Tabriz University of Medical Sciences, Tabriz, IR Iran

Mahdi Rahbar

Post-Graduate Student, Department of Operative and Esthetic Dentistry, Tabriz University of Medical Sciences, Tabriz, IR Iran

Hadi Shirvani

۴Master Student, Faculty of Electrical and Computer Engineering, Tabriz University, Tabriz, IR Iran