A Feasibility Study to Reduce the Contamination of Photoneutrons and Photons in Organs/Tissues during Radiotherapy
محل انتشار: مجله فیزیک پزشکی ایران، دوره: 17، شماره: 6
سال انتشار: 1399
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 412
فایل این مقاله در 8 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-17-6_003
تاریخ نمایه سازی: 19 دی 1399
چکیده مقاله:
Introduction: Due to out-of-field effects in radiation therapy, the determination and reduction of both unwanted photon and photoneutron doses are essential for the reasonable assessment of the risks to healthy tissues. Material and Methods: By the application of a multilayer shield throughout the phantom and using two models for photoneutron and photon sources, doses were estimated in a 15-MV linac in tissues and organs. Different neutron moderators were used, and the best materials, such as polyethylene, polystyrene, polyvinyl chloride, paraffin, and water, were reported for shielding purpose. Boron carbide and steel were utilized as neutron and gamma absorbents. Various lengths of the shield in line with phantom stature were also assessed in this study. Results: Except for the target organ, with the shield throughout the phantom, both photoneutron and photon doses approximately reduced by 57-89% and 88-95%, respectively. Extra photoneutron dose in the photon source was also reported due to the shield. Then, unwanted doses, especially photon dose remarkably decreased with increasing the steel thickness. The smaller dimensions of the shield caused also a considerable reduction of the photoneutron and photon doses in the phantom. Conclusion: The application of a multilayer shield reduces the photon dose remarkably in healthy tissues. Therefore, it is recommended to use shielding materials to decrease photoneutron and photon doses, which can cause a reduction in the risk of secondary cancer. Due to the relatively high mass of the shield, it is necessary to design a proper device to maintain and move the structure.
کلیدواژه ها:
نویسندگان
Roya Boodaghi malidarre
Department of Physics, Payame Noor University (PNU), Tehran, Iran, Postal code: ۱۹۳۹۵-۳۶۹۷
Rahim Khabaz
Department of physics, Faculty of science, Golestan University, Gorgan, Iran
Mohammad reza Benam
Department of Physics, Payame Noor University (PNU), Tehran, Iran, Postal code: ۱۹۳۹۵-۳۶۹۷
Vahid Zanganeh
Golestan university faculty of science, department of physics, Golestan, Iran
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :