Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by guidelines. If the validity of 99mTc-DMSA scan for renal size assessment would be established and reported in routine clinical practice, it might be more helpful for diagnostic purposes obviating further modality use in kidney diameter assessment. Methods:70 patients (25 males and 45 females) with the age range of 1 month to 78 years old (Mean ± SD = 18.1 ± 19.3) were included in the study. The longest axis diameter of each kidney was calculated by ultra sonography and planar 99mTc-DMSA scintigraphy. The difference in renal size estimation between US and different projections of 99mTc-DMSA scan was assessed using generalized linear model repeated measurement, pair wise comparison in Post Hoc and Bland-Altman analysis. Results:16 (22.9%) reports were interpreted as normal study, while 54 patients had abnormality at least in one kidney. No significant difference was noticed between the kidney diameters in US as compared to the all views of 99mTc-DMSA scan. Only in the estimation of left kidney size using 99mTc-DMSA scan, there was significant difference between anterior and posterior oblique views as well as between lateral and posterior oblique views. Mean value of the differences (estimated bias) doesn t differ significantly from 0 on the basis of 1-sample t-test. Conclusion: 99mTc-DMSA scintigraphy is an accurate method for renal length measurement with excellent agreement with ultra sonography. Kidney length can be easily measured as a routine processing procedure of a 99mTc-DMSA scan and not only used for more accurate interpretation of the images but also added to the final report as valuable incremental information.

نویسندگان

Sousan Shafiei

Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

Vahid-Reza Dabbagh

Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

Hamideh Sadra

Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

Ramin Sadeghi

Nuclear Medicine Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Lin E, Connolly LP, Zurakowski D, DiCanzio J, Drubach L, ...
  • Kim BW, Song MK, Chung S, Kim KS. Evaluation of ...
  • Otiv A, Mehta K, Ali U, Nadkarni M. Sonographic measurement ...
  • Prasad MM, Cheng EY. Radiographic evaluation of children with febrile ...
  • Lobo Sotomayor G, Ladrón de Guevara Hernández D, Arnello Viveros ...
  • Piepsz A, Colarinha P, Gordon I, Hahn K, Olivier P, ...
  • Estorch M, Torres G, Camacho V, Tembl A, Prat L, ...
  • Khazaei MR, Mackie F, Rosenberg AR, Kainer G. Renal length ...
  • Cao X, Zurakowski D, Diamond DA, Treves ST. Automatic measurement ...
  • Wallin L, Thörne J, Palmer J, Bajc M. Kidney size ...
  • Sisayan RM, Rossleigh MA, Mackey DW. Nomograms of renal length ...
  • Rossleigh MA, Farnsworth RH, Leighton DM, Yong JL, Rose M, ...
  • نمایش کامل مراجع