The investigation of absorbed dose in gastroesophageal reflux imaging procedure in children and neonates

سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 325

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

RINMMICMED22_085

تاریخ نمایه سازی: 30 آذر 1398

چکیده مقاله:

Background: Nuclear medicine techniques have been widely employed in the assessment of gastroesophageal dysfunction. Photon sources are used for many applications, especially in medicine imaging. Milk scan is used as a sensitive and accurate method for diagnosing GERD in children. The aim of this study is to estimate the amount of absorbed doses in the organs of the stomach, esophagus, and lung of children and infants, who suffer from GERD, using the nuclear imaging.Methods: By using the computational phantoms of (ORNL) and the MCNPX code in the Monte Carlo method, the absorbed dose of the 99mTc source was calculated as for different age groups. In this test, a certain radiopharmaceutical, which is often 99mTc colloid sulfur, is mixed with the breast milk or milk powder and will be given to the child. After entering the stomach, this radiopharmaceutical will go to an area in the esophagus and will be detected and imaged using the gamma camera.Results: Results from the gamma dosimeter calculation, in which stomach has the highest absorbed dose from photon radiation because this radiopharmaceutical has the maximum accumulation in this organ. It is noteworthy that all the results in this study have a very good agreement with what Samber reported. The obtained results revealed that the absorbed energy fraction in the organs of the esophagus and lung has an inverse relationship with the distance the source organ. The organ, which absorbs the most doses from gamma radiation, is stomach and this is expected because we defined the organ in the calculation code as the radiation source. Our study also shows a correlation between the age of the patients investigated and the rate of their absorbed dose, older children showing an absorbed dose is decreased than younger children.Conclusion: The major objective of the present study is to diagnose GERD, using the labeled colloid sulfur radiopharmaceutical with 99mTc, to take the maximum absorbed dose in the stomach and the minimum dose in the organs of the esophagus and lung to create the maximum of effect for imaging and the minimum of complications.

کلیدواژه ها:

نویسندگان

Zahra sadat Esmati

Department of Physics, Payame Noor University, Mashhad

Seyedeh fatemeh Khatani

Department of Pediatrics, Ghaem Hospital, Mashhad University of Medical Sciences

Parviz Parvaresh

Department of Physics, Payame Noor University, Mashhad