Impact Analysis of Variation in Geometrical Features on Intrinsic Characteristics of Capacitive Micro-machined Ultrasonic Transducers

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 235

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJE-31-11_006

تاریخ نمایه سازی: 10 آذر 1398

چکیده مقاله:

Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the parameters. In this paper, analytical model of circular CMUTs is developed and analyzed by using the parallel-plate capacitor equations. The impact of geometrical changes has been discussed with the parametric analysis of deflection, capacitance, pull in voltage and pressure. The results discussed here will be more helpful in deciding the miniaturization limit of the CMUT prior to fabrication.

نویسندگان

R. Sharma

Amity School of Engineering & Technology, Amity University Uttar Pradesh, Noida, India

R. Agarwal

Amity School of Engineering & Technology, New Delhi, India

A. K. Dubey

Amity School of Engineering & Technology, Amity University Uttar Pradesh, Noida, India

A. Arora

Thapar University, Patiala, Punjab, India