Internal and Marginal Fit of Modern Indirect Class II Composite Inlays
سال انتشار: 1393
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 300
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JDMT-3-3_002
تاریخ نمایه سازی: 20 مهر 1398
چکیده مقاله:
Introduction: This in vitro study investigates the marginal and internal fit of indirect class II composite restorations. Two different processes for chair-side restorations were compared. In group A, the restorations were fabricated using CAD/CAM technology (Cerec, Sirona, Germany, Bernsheim) and in group B they were made by hand (GrandioSO Inlay System, VOCO GmbH, Germany, Cuxhaven). Methods: For a metal tooth with a MOD cavity each 10 restorations were made for groups A and B. For each restoration, a replica of the cement-gap made from light body silicone was produced by placing the restoration into the cavity of the metal tooth. For this purpose, a special restoration-positioning machine was developed. Each replica was sectioned off in the longitudinal axis (L) and in the cross axis (C). The thickness of the replicas was measured in both directions, using picture analysis software under a light reflection microscope. To evaluate the fit of the restorations, a special fitting parameter was calculated. Statistical analysis was performed with the t test. Results: The fitting-parameter in group B (L: 97.6µm±73.0µm; C: 71.8µm±46.4µm) was significantly lower than that of group A (L: 155.1µm±102.3.0µm; C: 168.2µm±91.9µm) (P<0,001). Conclusions: Within the limitations of this in-vitro study hand-made composite restorations using the GrandioSO Inlay System seems to be a good alternative to CAD/CAM production. The clinical success of these restorations has to be evaluated in further studies.
کلیدواژه ها:
نویسندگان
Philipp C. Pott
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany
Agnieszka Rzasa
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany
Meike Stiesch
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany
Michael Eisenburger
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :