Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

سال انتشار: 1391
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 266

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_IJMP-9-3_006

تاریخ نمایه سازی: 20 مهر 1398

چکیده مقاله:

Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Results Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m3)/(track/cm2) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m3). With replacing the skin instead of CR-39, the volume affected by Radon and progeny was determined to be 2.51 mm3 for one m2 of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m3). Conclusion Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m3).

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Rehman FU, Jamil K, Zakaullah M, Abu-Jarad F, Mujahid SA. ...
  • Nikezić D, Yu KN. Monte Carlo calculations of LR115 detector ...
  • Paul H. A comparison of recent stopping power tables for ...
  • Yu K, Yip C, Nikezic D, Ho J, Koo V. ...
  • Rickards J, Golzarri JI, Espinosa G. A Monte Carlo study ...
  • Bianco SJ. Computer Physics Research Trends: Nova Science Publishers; 2007. ...
  • Nikezić D, Kostić D, Krstić D, Savović S. Sensitivity of ...
  • Kappel R, Keller G, Nickels R, Leiner U. Monte Carlo ...
  • Environmental Protection Agency. National Primary Drinking Water Regulations  Radon -222. ...
  • Sima O. Monte Carlo simulation of Radon SSNT detectors. Radiation ...
  • Vip WY. Retrospective Radon progeny dosimetry. PhD. Thesis: City University ...
  • Law Y, Nikezic D, Yu K. Optical appearance of alpha-particle ...
  • Khan RFH, Ahmad N. Studying the response of CR-39 detectors ...
  • Lopez  FO, Canoba  AC. Passive Method for the Equilibrium Factor ...
  • Banjanac R, Dragić A, Grabež B, Joković D, Markushev D, ...
  • Geiger H, Marsden E. On a Diffuse Reflection of the ...
  • Available from:  http:// www.vattenfall.com  ...
  • Nikezic D, Lau BM, Stevanovic N, Yu KN. Absorbed dose ...
  • Henshaw D, Fews A, Keitsch P, Wilding R, Close J, ...
  • Iacob O, Grecea C, Capitanu O, Rascanu V, Agheorghiesei D, ...
  • Ryan T, Sequeira S, Mckittrick L,ColganP.Radon in drinking water in ...
  • Kendall GM, Smith TJ. Doses to organs and tissues from ...
  • Available from: http://www.unscear.org/docs/reports/1993. ...
  • Hernandez DJ, Health NRCCot, Children AoI, Families, Health Cot. Children ...
  • نمایش کامل مراجع