Inspection of Pipes by Non-Axisymmetric Ultrasonic Guided Waves

سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 482

فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ICTINDT03_031

تاریخ نمایه سازی: 18 مرداد 1398

چکیده مقاله:

Ultrasound guided wave testing is a novel technique for inspection of various waveguides including pipe structures. Guided waves are ultrasonic waves that propagate differently from the more commonly known bulk waves. The use of axisymmetric guided modes has shown advantages of good penetration and good sensitivity. For a better understanding of the propagation and reflection of these waves in pipe structures, an experimental study of non-axisymmetric modes is carried out in this paper. The bubbler immersion ultrasonic testing technique, which incorporates a plastic wedge, provides a specific incident angle for the transducer. This specific incident angle produces the desired L(0,2) mode in the pipe, although some other flexural modes are also generated due to beam spreading. Using this setup, experiments are conducted on a steel pipe and the results are reported. Additionally, a wavelet analysis used to enhance the sensitivity of the approach. The non-axisymmetric ultrasonic guided waves seem to be a faster and simpler approach for inspection of pipe structures.

نویسندگان

Hamed Bouzary

MSc student, Faculty of Mechanical Engineering, K. N. Toosi University of Technology;

Farhang Honarvar

Professor, Faculty of Mechanical Engineering, K. N. Toosi University of Technology;

Sara Maghami

MSc student, Faculty of Mechanical Engineering, K. N. Toosi University of Technology;