Air oxidized titanium dental implant

سال انتشار: 1397
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 503

نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

ITERMED01_056

تاریخ نمایه سازی: 7 مرداد 1398

چکیده مقاله:

IntroductionThe bioinertness, makes surface treatments essential for titanium implants to improve their bioactivity or bone bonding ability. Air oxidation is a simple method for surface modification of titanium.MethodsIn this research, the effect of thermal oxidation of rigid titanium dental implant at 600˚C on its surface properties was studied.ResultsThe results of X-ray diffraction and scanning electron microscopy (SEM) indicated that the surface of heat treated titanium implants mainly covered by rutile nano particles. Also, wettability measurement indicated that hydrophilicity of titanium surface was increased by air oxidation. So it seems atmospheric oxidation of titanium dental implant improves its surface properties for in vivo implantation

نویسندگان

Mohammad Khodaei

Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

Akram Alizade

Cellular and Molecular Research Center, Basic Health Sciences Institute, Shahrekord University of Medical Sciences, Shahrekord, Iran