Uptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease
سال انتشار: 1396
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 321
فایل این مقاله در 7 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JNMB-5-1_005
تاریخ نمایه سازی: 12 تیر 1398
چکیده مقاله:
Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ratio is useful for distinguishing LBD from non-LBD, it fluctuates depending on the system performance of the gamma cameras. Therefore, a new, simple quantification method using 123I-MIBG uptake analysis is required for clinical study. The purpose of this study was to develop a new uptake index with a simple protocol to determine 123I-MIBG uptake on planar images.Methods: The 123I-MIBG input function was obtained from the input counts of the pulmonary artery (PA), which were assessed by analyzing the PA time-activity curves. The heart region of interest used for determining the H/M was used for calculating the uptake index, which was obtained by dividing the heart count by the input count.Results: Forty-eight patients underwent 123I-MIBG chest angiography and planar imaging, after clinical feature assessment and tracer injection. The H/M and 123I-MIBG uptake index were calculated and correlated with clinical features. Values for LBD were significantly lower than those for non-LBD in all analyses (P<0.001). The overlapping ranges between non-LBD and LBD were 2.15 to 2.49 in the H/M method, and 1.04 to 1.22% in the uptake index method. The diagnostic accuracy of the uptake index (area under the curve (AUC), 0.98; sensitivity, 96%; specificity, 91%; positive predictive value (PPV), 90%; negative predictive value (NPV), 93%; and accuracy, 92%) was approximately equal to that of the H/M (AUC, 0.95; sensitivity, 93%; specificity, 91%; PPV, 90%; NPV, 93%; and accuracy, 92%) for discriminating patients with LBD and non-LBD.Conclusion: A simple uptake index method was developed using 123I-MIBG planar imaging and the input counts determined by analyzing chest radioisotope angiography images of the PA. The diagnostic accuracy of the uptake index was approximately equal to that of the H/M for discriminating patients with LBD and non-LBD.
کلیدواژه ها:
نویسندگان
Yoshito Kamiya
Graduate School of Health Sciences, Kumamoto University, Kuhonji ۴-۲۴-۱, Chuo-ku, Kumamoto ۸۶۲-۰۷۹۶, Japan
Satoru Ota
Graduate School of Health Sciences, Kumamoto University
Shintaro Okumiya
Graduate School of Health Sciences, Kumamoto University
Kosuke Yamashita
Fujifilm RI Pharma Co.,Ltd.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :