چکیده مقاله:
Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and validate the Southampton method using a three-dimensional mathematical cylinder (3D-MAC) phantom.Methods: We used ROIs sizes of 27, 36, 44, 51, 61, 68, and 76 mm for targets with diameters 40, 20, and 10 mm on reference and processed images reconstructed using the 3D-MAC phantom. Contrast values and SBR were compared with the theoretical values to obtain the optimal ROI size.Results: The contrast values in the ROI with diameters of 51 (target: 40 mm in diameter) and 44 (target: 20 mm in diameter) mm matched the theoretical values. However, this value did not correspond with the 10-mm-diameter target. The SBR matched the theoretical value with an ROI of > 44 mm in the 20-mm-diameter target;but, it was under- and overestimated under any other conditions.Conclusion: These results suggested that an ROI should be 4-2 folds larger than the target size without PVE, and that the Southampton method was remarkably accurate.
کلیدواژه ها:
نویسندگان
Hideo Onishi
Program in Health and Welfare Graduate School of Comprehensive Scientific Research Prefectural university of Hiroshima
Takayuki SAKAI
۱-۱, Sonekitamachi, Kokura-Minami-ku, Kitakyusyu, Fukuoka, ۸۰۰-۰۲۹۶, Japan
Osamu SHIROMOTO
Program in Health and Welfare Graduate School of Comprehensive Scientific Research, Prefectural University of Hiroshima ۱-۱, Gakuenmachi, Mihara, Hiroshima, ۷۲۳-۰۰۵۳, Japan
Hizuru Amijima
Department of Nursing,Hyogo University of Health Sciences
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :