Damping analysis of sub-synchronous resonance (SSR) in a wind farm based on DFIG in a series compensated network

سال انتشار: 1397
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 493

فایل این مقاله در 12 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_EES-6-4_004

تاریخ نمایه سازی: 12 خرداد 1398

چکیده مقاله:

The effect of wind generator on sub-synchronous resonance (SSR) is being interested by increasing penetration of wind turbine in power systems,. Purpose of this article is to analyze SSR in a wind farm based on doubly fed induction generator (DFIG) which is connected to compensating series grid. A dynamic model for analysis of induction generator effect and Torsional Interaction (TI) has been utilized and simulated. The IEEE first benchmark model, is modified to include a 100 MW DFIG-based wind farm, is employed as a case study. three phenomena including a) series compensation level, b) the rotor speed, and c) effect of internal parameters of RSC controller on SSR are evaluated and the simulation results are analyzed.

نویسندگان

Ali Ghasemi

Faculty of Electrical and Computer Engineering Shahid Rajaee Teacher Training University, Tehran, Iran

Mohammad Hossein Refan

Faculty of Electrical and Computer Engineering Shahid Rajaee Teacher Training University, Tehran, Iran

Parviz Amiri

Faculty of Electrical and Computer Engineering Shahid Rajaee Teacher Training University, Tehran, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Kundur P., Power System Stability and Control. New York: McGraw ...
  • Chuangpishit S., Tabesh A., Moradi-Sharbabk Z., Saeedifard M., Topology Design ...
  • Fan L., Kavasseri R., Miao Z. L., Zhu Ch., Modeling ...
  • Mohammadpour H.A., Ghaderi A., Santi E., Analysis of Sub-Synchronous Esonance ...
  • Varma R., Auddy S., Semsedini Y., Mitigation of Subsynchronous Resonance ...
  • Ostadi A., Yazdani A., Varma R., Modeling and Stability Analysis ...
  • Zhu C., Fan L., Hu M., Modeling and Simulation of ...
  • Jesus F. de, Watanabe E., Souza L. de, Alves J., ...
  • Kumar L. S., Ghosh A., Modeling and Control Design of ...
  • IEEE Committee Report, First Benchmark Model for Computer Simulation of ...
  • Fernandez L. M., Jurado F., Saenz J. R., Aggregated Dynamic ...
  • Bialasiewics J. T., Muljadi E., The Wind Farm Aggregation Impact ...
  • Muljadi E., Parsons B., Comparing Single and Multiple Turbine Representations ...
  • Karaagac U., Faried S.O.O., Mahseredjian J., Edris A., Coordinated Control ...
  • Omar Faried S., Unal I., Rai D., Mahseredjian J., Utilizing ...
  • Mei F., Pal B., Modal Analysis of Grid-Connected Doubly Fed ...
  • Leon A.E., Mauricio J.M., Solsona J.A., Subsynchronous Resonance Mitigation ...
  • Using Variable Speed Wind Energy Conversion Systems, IET Generation, Transmission & Distribution (2012): 511–525. ...
  • Lei Y., Mullane A., Lightbody G., Yacamini R., Modeling of ...
  • Miao Z., Fan L., The Art of Modeling High-order Induction ...
  • Mei F.,  Pal. B. C., Modelling of Dobuly-Fed Induction Generator ...
  • نمایش کامل مراجع