Novel methodology in design of custom-made femoral stem

سال انتشار: 1388
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 1,662

فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

NMEC02_058

تاریخ نمایه سازی: 14 آبان 1388

چکیده مقاله:

Medical applications of rapid prototyping (RP) have an increasing trend, making the future of RP more and more promising. These applications may include design,development, and manufacture of medical devices and instrumentation, as well as implant design, anatomical models, surgical planning, surgical implants, and prosthesis fabrication. This paper will provide a new methodology in design of custom-made femoral stems that could provide optimal fill and fit for stems in individual femurs and result in optimize load transfer, minimize stem motion, increase initial stability and extend durability. Combinations of this methodology with RP technology can facilities manufacturing of custom-made femoral stem by considering time and economical aspects..

نویسندگان

F Abbaszadeh

M.Sc student, Science and Research Branch, Islamic Azad University

S. Rahmati

Associate Professor, Mechanical Engineering Group, Majlesi Branch, Islamic Azad University

F Farahmand

Professor, Mechanical Engineering Department,Sharif University of technology

H Sami

M.D, Orthopedic Surgeon

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Lا-dong, WU., et al _ 2004. The dimensional accuracy of ...
  • Adam, F., et al.2002. "Femoral anatomy, computed tomography and computer- ...
  • Walker PS (1987) Strains and micromotions of press-fit femoral stem ...
  • Zweymiller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of ...
  • Dalton, J. E., et al. 1995. The effect of operative ...
  • Nishihara, S., et al . 2003. " Comparison of the ...
  • Zweymiller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of ...
  • Mallory TH, Head WC, Lombardi AV (1997) Tapered design for ...
  • Robertson DD, Walker PS, Granholm JW, Nelson PC, Weis PJ, ...
  • Walker PS (1988) Design and fabrication of cementles hip stems. ...
  • Najafabad Conference on Manufactu ring Engineering (nmec2009) April 20-21, 2009, ...
  • Elke RP, Cheal EJ, Simmons C, Poss R (1995) Three-di ...
  • Mallory TH, Head WC, Lombardi AV (1997) Tapered design for ...
  • Sugano N, Ohzono K, Nishii T, Haraguchi K, Sakai T, ...
  • Aamodt A, Kvistad KA, Andersen E, Lund-Larsen J, Eine J, ...
  • Bargar WL (1989) Shape the implant to the patient. A ...
  • Capello WN (1989) Fit the patient to the prosthesis. An ...
  • Laine HJ, Kontola K, Lehto MU, Pitkanen M, Jarske P, ...
  • Singare, S. Dichen, L. Bingheng, L. Yanpu, L. Zhenyu, G.Yax ...
  • Winder, J. Bibb, R. 2005. Medical rapid prototyping technologies: state ...
  • Singare, S. Dichen, L. Bingheng, L. Zhenyu, G. Yaxiong, L. ...
  • Hieu, LC. Bohez, E. Vander, S., et al. 2003. Design ...
  • Morris, CL. Barber, RF. Day, R. 2000. Orofacial prosthesis design ...
  • T. 2004. Wohlers Report 2004: Rapid prototyping, tooling and ...
  • Najafabad Conference on Manufactu ring Engineering (nmec2009) April 20-21, 2009, ...
  • Hopkinson _ N. Hague, R. Dickens, P .2006. Rapid Manufacturing ...
  • Harrysson _ Ola. 2007. Custom-desig ned orthopedic implants evaluated using ...
  • Lorensen, W.Cline, H. 1987. A High Resolution 3D Surface Construction ...
  • GeoMagic User Manual, Raindrop Geomagic, Research Triangle, NC, USA; 2004. ...
  • Sun, W. Starly, B. Nam, J. Darling, A. 2005. Bio-CAD ...
  • Dai, K. R., et al. 1985. Geometric and biomechan ical ...
  • Laine, H., et al .2000. Diversity of proximal femoral medullary ...
  • Decking, J., et al. 2003. The internal calcar septum and ...
  • Noble, PC. Alexander, JW. Lindaul, LJ. Yew, DT. Granberry, WM. ...
  • Nishihara, S., et al. 2004.Clinicl accuracy evaluation of femoral canal ...
  • Merloz, P , et al, . "Computer assisted hip surgery ...
  • LIU Jian-guo et al _ 2004. computer assisted reconstruction of ...
  • Xu, QR., et al. 2002. The aspetic loosening and osteolysis ...
  • Martini, F., et al. 2000. Precision of the reconstruction of ...
  • Najafabad Conference on Manufactu ring Engineering (nmec2009) April 20-21, 2009, ...
  • Negre, J., et al.1995. bone reaction to contact with a ...
  • Viceconti, M., et al. 2001. A new hybrid environment for ...
  • Bargar, WL. Bauer, A. Borner, M. 1989. Primary and revision ...
  • Lin, Y., et al. 2005. Reverse engineering in CAD modl ...
  • Harrysson _ Ola, Cormier, D. 2006. Direct fabrication of custom ...
  • نمایش کامل مراجع