Applicable spectrophotometric determination of trace amount of lead in human blood serum of miners by fast and precise liquid-liquid extraction method and comparison with AAS method
سال انتشار: 1392
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 515
نسخه کامل این مقاله ارائه نشده است و در دسترس نمی باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ACPLMED15_024
تاریخ نمایه سازی: 20 آبان 1397
چکیده مقاله:
In order to remove the interference of blood proteins and other compounds, Silica gel columnwas used for preparation of human serum of miners by washing the column with deionizedwater, adjusting pH with phosphate buffer and then adding tartrate and cyanide solutions asmasking agents, the extraction of Pb (II) from the aqueous phase into the organic phasecontaining Dithizone as a complexing reagent was performed by shaking the appropriate testtube for two minutes. Then the complex Pb (II)-Dithizone was determinedspectrophotometrically. Calibration graph was linear in the range of 0.1-1.5 fJ.g ml-1 of Pb.The results were in good agreement with those obtained by atomic absorption spectrometryresults.
کلیدواژه ها:
نویسندگان
Abolfazl Ghafori Khosroshahi
Hamadan University, Hamadan, Iran
Leila Mousavi
Hamadan University, Hamadan, Iran
Tavakol Heidary Shayeste
Hamadan University, Hamadan, Iran