Electrochemical behavior of an anicancer drug and its determination in pharmaceutical formulation by cyclic and differential-pulse voltametric techniques at glassy carbon electrode
محل انتشار: چهارمین کنفرانس بین المللی علوم و مهندسی
سال انتشار: 1395
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 655
فایل این مقاله در 16 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
این مقاله در بخشهای موضوعی زیر دسته بندی شده است:
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ICESCON04_314
تاریخ نمایه سازی: 25 آذر 1395
چکیده مقاله:
Tamoxifen (Tam) is an anticancer drug used in the treatment breast cancer. In this work, the electrochemical behavior of (Tam) were investigated by cyclic (CV) and differential-pulse anodic adsorptive striping (DPAAS) voltammetric techniques at different electrodes such as glassy carbon (GC), Au and Pt electrode in H2SO4 at different concentration. It was observed that at GCE electrocatalytic behavior for the oxidation of Tam was excellent. It was evidenced by the enhancement of oxidation peak current and shift in the oxidation potential to less positive values. Cyclic voltammetry (CV) and chronoamperometry were used to understand the electrochemical characteristics of Tam. A chronoamprograms gave fundamental electrochemical parameter including the electroactive surface coverage (), the diffusion coefficient (D) and the heterogeneous rate constant (ks). Based on the results of the recorded CV, the electrodeposition and anodic striping behavior of the Tam were investigated at the surface of GCE. The primary experiments demonstrated that the DPAASV presents a sufficient oxidation peak current at approximately 1.03 V vs Ag/AgCl. Therefore, to find the best conditions for taking a sharp analytical peak concerning the electro-oxidation of Tam, the effects of different factors such as scan rate, deposition potential, deposition time and concentration of H2SO4 on anodic peak have been studied and optimized. A DPV method with good precision and accuracy was developed for the determination of Tam in pharmaceutical formulations. The calibration curve showed linearity in the range of 0.5 to 80 μM and the limits of detection (LOD) and quantitation (LOQ) were calculated to be 0.12 and 0.4 μM, respectively. The mean, standard error and relative standard deviation (RSD) for 4 replicates of 15 μM were found to be 15.57 μM, 3% and 4%, respectively.
کلیدواژه ها:
نویسندگان
Z. Deris Falahiye
Department of Chemistry, Faculty of Science, Islamic Azad University, Arak Branch, P.O.B
M. Jalali
Department of Chemistry, Faculty of Science, Islamic Azad University,Omidiyeh Branch, P.O.B:
M. Alimoradi
Department of Chemistry, Faculty of Science, Islamic Azad University, Arak Branch, P.O.B
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :