A high CMRR low noise CMOS amplifier for electrocardiogram signal recording applications

سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 840

فایل این مقاله در 6 صفحه با فرمت PDF قابل دریافت می باشد

این مقاله در بخشهای موضوعی زیر دسته بندی شده است:

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

NCNIEE04_107

تاریخ نمایه سازی: 25 آذر 1395

چکیده مقاله:

Electrocardiogram signal and other biomedical signals are low frequency and low amplitude signals. This article proposes a high CMRR low noise wide linear output range biopotential CMOS amplifier for electrocardiogram signal recording applications and physiological measurement frontend. The wide linear output range is achieved by effectively combining the first-stage open-loop and the second-stage closed-loop configuration, and using additional gain enhancement switches. Due to the wide linear output range, the proposed amplifier shows a stable voltage gain of 46.3 dB for output range from 0.15 to 3.12 V and THD of 0.04% with a 15 mVpp input amplitude (all with 3.3 V supply).

نویسندگان

Seyed Ali Navabi Kerdabadi

Department of Electronic engineering, Khorasgan Branch, Islamic Azad University, Isfahan, Iran

Minasadat Hoseini

Department of Electronic engineering, Khorasgan Branch, Islamic Azad University, Isfahan, Iran

Bashir Najafabadian

Department Department of Biomedical engineering, Science and Research Branch, Islamic Azad

Hosein Hamidipour

Department of Electronic engineering, Khorasgan Branch, Islamic Azad University, Isfahan, Iran

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • P. C. Crepaldi, T. C. Pimenta, R. L. Moreno, and ...
  • Bashir Najafabadian, Hajar Baghoolizadeh, Elham Asadi, Ahmad Najafabadian 2013 A ...
  • _ _ _ _ Ahmad Najafabadian 2013 A novel method ...
  • _ _ . Ahmad Najafabadian 2013 ECG amplifier design with ...
  • Bashir Najafabadian, Ahmad Najafabadian , Taherehsadat ...
  • stimulation with transdermal amplitude modulated signal _ International Conference in ...
  • _ _ A. _ feedback instrumentation amplifier with 5 , ...
  • B. B. Winter and J. G. Webster, "Reduction of interference ...
  • A. L. Goldberger et al., "PhysioBank, PhysioToolkit, and PhysioNet: Components ...
  • W. Besio and A Prasad, "Analysis of skin-electrode impedance using ...
  • _ _ _ _ DC-coupled neural signal acquisition IC with ...
  • _ _ _ _ applications, " IEEE Trans. Biomed. Circuits ...
  • Y. Tseng, Y. Ho, S. Kao, and H. Su, "A ...
  • B. Johnson and A. Molnar, _ orthogonal current-reuse amplifier for ...
  • _ _ _ _ _ Conf. Dig. Tech. Papers, Feb. ...
  • D. Han, Y. Zheng, R. Rajkumar, G. Dawe, and M. ...
  • wireless blood pressure biosensor, " IEEE Trans. Instrum. Meas., vol. ...
  • L. Fanucci et al, "Sensing devices and sensor signal processing ...
  • J. Yoo, L. Yan, D. El-Damak, M. A. B. Altaf, ...
  • _ _ _ circuit, " IEEE Trans. Biomed. Circuits Syst., ...
  • R. Rieger and S.-L. Deng, _ 'Double- differential recording and ...
  • [6] H. Zare-Hoseini, I. Kale, and O. Shoaei, "Modeling of ...
  • K. Abdelfattah and B. Razavi, "Modeling op amp nonlinearity in ...
  • _ _ _ _ simple modeling of amplifier dc gain ...
  • _ F. A. _ portable EEG acquisition systems, " IEEE ...
  • Y.-Q. Zhao, A. Demosthenous, and R. H. Batford, "A CMOS ...
  • C. Nanda, J. Mukhopadhyay, D. Mandal, and S. Chakrabarti, "1 ...
  • A. Worapishet, A. Demosthenous, and X. Liu, "A CMOS instrumentation ...
  • H. Alzaher and M. Ismail, "A CMOS fully balanced ...
  • no. 6, pp. 614-620, Jun. 2001. ...
  • Bashir Najafabadian, Hajar Baghoolizadeh, Mahtab Dadkhah tehrani, Minasadat Hoseini, Ahmad ...
  • _ _ _ _ _ Intelligent system design for real ...
  • نمایش کامل مراجع