Experimental Study of a Dead-End H2/O2 PEM Fuel Cell Stack with Unified Humidifier and Water Separator
محل انتشار: سومین کنفرانس ملی و اولین کنفرانس بین المللی پژوهش هایی کاربردی در مهندسی برق، مکانیک و مکاترونیک
سال انتشار: 1394
نوع سند: مقاله کنفرانسی
زبان: انگلیسی
مشاهده: 861
فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ELEMECHCONF03_0237
تاریخ نمایه سازی: 9 مرداد 1395
چکیده مقاله:
Proton exchange membrane fuel cells (PEMFCs) with a dead-ended anode and cathode can obtain high hydrogen and oxygen utilization by a comparatively simple system. Nevertheless, the accumulation of the water in the anode and cathode channels can lead to a local fuel starvation, which degrades the performance and durability of PEMFCs. In this paper for the first time, a new design for a polymer electrolyte membrane (PEM) fuel-cell stack is presented which can achieve higher fuel utilization without using hydrogen and oxygen recirculation devices such as hydrogen pumps or ejectors, that consumes parasitic power and require additional control schemes. The humid and water separator sections are integrated with stack and extremely reduced the size and volume of stack. For effective water removal and increasing local stoichiometry, stack is divided to blocks by conducting the outlet gas of first stage to a separator and reentering to second stage. The active area of cell is 225 cm2 (15 cm×15 cm) and there are 3cell at first stage and 1 cell in second stage. In this design, a higher gaseous flow rate is maintained at the outlet of the first stage cells, even under dead-end conditions, and this results in a reduction of purge-gas emissions by hindering the accumulation of liquid water in the cells. The result shows that with this novel design the higher efficiency can be achieved, although the weight, volume and size of stack are decreased.
کلیدواژه ها:
Standard Ventilation ، Cross Section Leakage ، Minimum Discharge Flow Rate ، Hydrogen Laboratory ، Fuel Cell Test Station
نویسندگان
E. Alizadeh
Malek-Ashtar University of Technology, , Fuel Cell Technology Research Laboratory, Fridonkenar, Iran.
M. Khorshidian
Malek-Ashtar University of Technology, , Fuel Cell Technology Research Laboratory, Fridonkenar, Iran.
S. H. M. Saadat
Malek-Ashtar University of Technology, , Fuel Cell Technology Research Laboratory, Fridonkenar, Iran.
مراجع و منابع این مقاله:
لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :