Combining pre-sedimentation with roughing filters: experimental evaluation of effective hydraulic parameters using a physical model
سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: فارسی
مشاهده: 25
فایل این مقاله در 25 صفحه با فرمت PDF قابل دریافت می باشد
- صدور گواهی نمایه سازی
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_NAWEE-5-4_004
تاریخ نمایه سازی: 22 آبان 1405
چکیده مقاله:
Objective: Treatment of highly turbid surface water remains challenging in low-cost decentralized systems. This study aims to evaluate the hydraulic performance of a novel integrated pre-sedimentation and multilayer horizontal roughing filtration system and to develop dimensionless design relationships for improved process optimization and scale-up. Methods: A laboratory-scale physical model was constructed in a hydraulic flume at the Khuzestan Water and Power Authority, Iran. The system combined a ۱ m stilling basin with a three-layer roughing filter (۲۰ mm, ۱۰ mm, and ۲ mm media). Experiments were conducted under three filter lengths (۲۶۰, ۳۵۰, and ۴۵۰ cm), three filtration velocities (۰.۲۰, ۰.۶۰, and ۱.۰۰ m h⁻¹), three operation times (۱۰, ۲۰, and ۳۰ min), and three influent turbidity ranges (۱۵۰۰–۲۵۰۰ NTU), resulting in ۸۱ experimental runs. Turbidity removal efficiency was used as the performance criterion, and input predictability was assessed using the Gamma Test. Results: Filter length was identified as the dominant parameter, improving removal efficiency by approximately ۹–۱۰% when increased from ۲۶۰ to ۴۵۰ cm. Maximum efficiencies exceeded ۹۴% at ۰.۲۰ m h⁻¹ and ۴۵۰ cm length. Filtration velocity had a secondary negative effect (۴–۵% reduction across the tested range), while influent turbidity and operating time showed limited influence. The Gamma Test confirmed strong deterministic structure in the full-input configuration (Gamma = ۰.۰۴۶۲; V-ratio = ۰.۱۸۴۸). Conclusions: The findings demonstrate that, within the tested range, increasing the effective length of the multilayer horizontal roughing filter improved turbidity removal performance and enhanced the overall efficiency of the combined pre-sedimentation–filtration system. These results indicate that filter length is an important design parameter for treating highly turbid surface waters in resource-limited regions. However, the present study should be interpreted as an experimental performance assessment of selected configurations rather than a formal geometric optimization, and determination of the absolute optimal design would require further investigation over a wider range of configurations together with techno-economic evaluation.
کلیدواژه ها:
نویسندگان
بهروز بهزادفر
Department of Water Science Engineering, Ahv.C., Islamic Azad University, Ahvaz, Iran.
حیدرعلی کشکولی
Department of Water Science Engineering, Ahv.C., Islamic Azad University, Ahvaz, Iran.
هوشنگ حسونی زاده
Khuzestan Water and Power Organization, Ahvaz, Khuzestan, Iran
محمد حیدرنژاد
Department of Water Science Engineering, Ahv.C., Islamic Azad University, Ahvaz, Iran