Field Evaluation of LPG Consumption and Operational Performance in a Crematorium Furnace Before and After Electrostatic Fuel-Conditioning Retrofit

سال انتشار: 1405
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 19

فایل این مقاله در 14 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JEWE-12-3_002

تاریخ نمایه سازی: 22 آبان 1405

چکیده مقاله:

This study examined changes in LPG consumption and cremation cycle duration following installation of an electrostatic fuel-conditioning device (E.R.S. “Gass Saver”) on a ۱۷-year-old crematorium furnace in Bangkok, Thailand. The sequential before–after study covered ۴۰ cremation cycles (۲۰ per phase) under routine operation, without randomization or a control furnace. LPG consumption was measured gravimetrically, and cycle duration was recorded from burner ignition to operator-confirmed completion. Mean LPG consumption decreased from ۷۸ ± ۴ to ۵۹ ± ۳ kg per cremation (۲۴.۴%; Welch’s t-test based on summary statistics, p < ۰.۰۰۱; ۹۵% CI: ۱۶.۷–۲۱.۳ kg; Hedges’ g ≈ ۵.۳). Mean cycle duration decreased from ۱۲۰ to ۸۰ min (۳۳.۳%), although dispersion data were unavailable. Calculated fuel-energy input declined from ۳,۵۹۵.۸ to ۲,۷۱۹.۹ MJ per cremation, assuming a net calorific value of ۴۶.۱ MJ/kg. Estimated direct CO₂ reductions were ۵۷ kg per cremation (۱۳.۶۸ t/year at ۲۴۰ cremations), while annual fuel-cost savings were THB ۱۱۴,۰۰۰, assuming THB ۲۵/kg LPG. Because cremation workloads were not characterized and combustion performance was not measured, these differences cannot be attributed directly to the device. The proposed electrostatic mechanism also remains unverified. These preliminary findings warrant controlled trials with standardized workloads and independent replication.

نویسندگان

Wirote Ritthong

۱Faculty of Engineering and Technology, Shinawatra University, Pathum Thani ۱۲۱۶۰, Thailand ۲Faculty of Engineering, Bangkok Thonburi University, Bangkok ۱۰۱۷۰, Thailand ۳Research Fellow, INTI International University, Negeri Sembilan ۷۱۸۰۰,

Thakon Sawatdikumthon

Faculty of Liberal Arts, Krirk University, Bangkok ۱۰۲۲۰, Thailand

Naphat Albutt

Faculty of Engineering, Bangkok Thonburi University, Bangkok ۱۰۱۷۰, Thailand

Tadpon Kullawong

Faculty of Engineering and Technology, Shinawatra University, Pathum Thani ۱۲۱۶۰, Thailand

Khongdet Phasinam

۱Faculty of Engineering and Technology, Shinawatra University, Pathum Thani ۱۲۱۶۰, Thailand

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :
  • Ağbulut, Ü., Sarıdemir, S., Rajak, U., Polat, F., Afzal, A., ...
  • Kanneganti, H., Gopalakrishnan, B., Crowe, E., Al-Shebeeb, O., Yelamanchi, T., ...
  • Thairath Online. (۲۰۲۶, August ۸). Government caps LPG price at ...
  • Vergara-Hernández, C., Álvarez-Ojeda, A., Díaz-Caballero, A., & Plazas-Román, J. (۲۰۲۴). ...
  • نمایش کامل مراجع