Structured Verbal Analgesia Versus Neutral Communication During Copper T۳۸۰A IUD Insertion in Women with Previous Cesarean Delivery and No Prior Vaginal Birth: An Open-Label Randomized Controlled Trial

سال انتشار: 1406
نوع سند: مقاله ژورنالی
زبان: انگلیسی
مشاهده: 33

فایل این مقاله در 9 صفحه با فرمت PDF قابل دریافت می باشد

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این مقاله:

شناسه ملی سند علمی:

JR_JOGCR-12-1_010

تاریخ نمایه سازی: 22 آبان 1405

چکیده مقاله:

Background & Objective: Women with previous cesarean delivery and no prior vaginal birth may have more difficult and painful intrauterine device insertion, highlighting the need for simple non-pharmacologic pain-reduction strategies. The present study aimed to compare structured verbal analgesia vs. standardized neutral communication during Copper T۳۸۰A intrauterine device insertion in women with previous cesarean delivery and no prior vaginal birth. Materials & Methods: This open-label, parallel-group, randomized controlled trial with ۱:۱ allocation to structured verbal analgesia or standardized neutral communication, was conducted in the outpatient family planning and gynecology clinic of a tertiary referral hospital in Egypt from October ۲۰۲۵ to May ۲۰۲۶. Women aged ۱۸-۴۵ years who had delivered only by CD, with no prior vaginal birth, and who requested Copper T۳۸۰A insertion were enrolled. Insertion technique was the same in both arms. The primary outcome was pain on a ۰-۱۰ numerical rating scale, recorded immediately after IUD release or, in failed insertions, at the final attempted step. Analyses were performed using MedCalc statistical software (version ۲۲.۰). P<۰.۰۵ was considered significant. Results: Eighty-eight women were randomized, ۴۴ to each group. Pain at IUD release or final attempted insertion did not differ significantly between the two groups of structured verbal analgesia and standardized neutral communication (۴.۸±۱.۸ vs ۵.۲±۱.۹; mean difference -۰.۳۶; ۹۵% CI, -۱.۱۶ to ۰.۴۳; P=۰.۳۶). Step-specific pain scores, clinician-rated insertion difficulty, and procedure time were comparable. Failed insertion occurred in ۱ woman (۲.۳%) in the verbal analgesia group and ۲ women (۴.۵%) in the neutral communication group. Rescue analgesia, satisfaction, willingness to repeat the procedure, and vasovagal episodes were also similar. No uterine perforation occurred. At ۱ month, expulsion occurred in ۱/۴۱(۲.۴%) of the verbal analgesia group versus ۱/۳۹(۲.۶%) of the neutral communication group with completed follow-up. Conclusion: Structured verbal analgesia did not significantly reduce Copper T۳۸۰A insertion pain compared with standardized neutral communication. Larger trials are needed to determine whether smaller patient-important benefits exist.

نویسندگان

- -

Department of Obstetrics and Gynaecology, College of Medicine and Health Sciences, Arabian Gulf University, Manama, Bahrain

- -

Reproductive Health and Family Planning Department, National Research Centre, Cairo, Egypt

- -

Department of Obstetrics and Gynecology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

- -

Department of Obstetrics and Gynecology, Faculty of Medicine, Misr University for Science and Technology, Egypt

- -

Reproductive Health and Family Planning Department, National Research Centre, Cairo, Egypt

- -

Department of Obstetrics and Gynecology, Faculty of Medicine, Suez University, Suez, Egypt

- -

Department of Obstetrics and Gynecology, Faculty of Medicine, Suez Canal University, Ismailia, Egypt

مراجع و منابع این مقاله:

لیست زیر مراجع و منابع استفاده شده در این مقاله را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود مقاله لینک شده اند :